Suppr超能文献

CBCT 分析骨密度与种植体设计选择时的初期稳定性之间相关性的重要性——体外研究。

The Importance of Correlation between CBCT Analysis of Bone Density and Primary Stability When Choosing the Design of Dental Implants-Ex Vivo Study.

机构信息

Department of Dentistry, Faculty of Medicine, University of Montenegro, 81000 Podgorica, Montenegro.

Department of Dentistry, Faculty of Medicine, University of Pristina, 38220 Kosovska Mitrovica, Serbia.

出版信息

Tomography. 2022 May 11;8(3):1293-1306. doi: 10.3390/tomography8030107.

Abstract

This study aims to determine the correlation between the mean value of bone density measured on the CBCT device and the primary stability of dental implants determined by resonant frequency analysis. An experimental study was conducted on a material of animal origin: bovine femur and pig ribs. Two types of implants were used in this study: self-tapping and non-self-tapping of the same dimensions. Results of the experimental study showed a statistically significant correlation between bone density expressed in HU units and the primary stability of self-tapping and non-self- tapping dental implants expressed in ISQ units in bovine femur bones and self-tapping implants and pig rib bones. There was no statistically significant correlation between non-self-tapping dental implants in pig rib bones. Self-tapping and non-self-tapping implants did not show statistical significance in the primary stability in bones of different qualities. The analysis of bone density from CBCT images in the software of the apparatus expressed in HU units can be used to predict the degree of primary stability of self-tapping and non-self-tapping dental implants in bones of densities D1 and D2, and self-tapping dental implants in bones of the lower quality D4.

摘要

本研究旨在确定 CBCT 设备测量的骨密度平均值与共振频率分析确定的牙种植体初始稳定性之间的相关性。这项实验研究是在动物源性材料上进行的:牛股骨和猪肋骨。本研究使用了两种类型的种植体:相同尺寸的自攻型和非自攻型。实验研究结果表明,HU 单位表示的骨密度与 ISQ 单位表示的自攻型和非自攻型牙种植体在牛股骨和自攻型种植体中的初始稳定性之间存在统计学显著相关性。在猪肋骨中的非自攻型牙种植体之间没有统计学显著相关性。在不同质量的骨中,自攻型和非自攻型种植体的初始稳定性没有统计学意义。在 HU 单位表示的仪器软件的 CBCT 图像中分析骨密度,可以预测 D1 和 D2 密度骨中自攻型和非自攻型牙种植体以及 D4 质量较低的骨中自攻型牙种植体的初始稳定性程度。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/1eae/9149886/1481d0603038/tomography-08-00107-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验