Suppr超能文献

不同材料制成的球附着体与咀嚼模拟后根管牙本质的拉伸粘结强度比较。

Comparison of tensile bond strength of ball attachments made of different materials to root canal dentin after chewing simulation.

机构信息

Oral and Maxilofacial Prosthodontics Department, Faculty of Dentistry, AinShams University, Organization of African Unity Street, Cairo, 11561, Egypt.

Operative Dentistry Department, Faculty of Dentistry, AinShams University, Cairo, Egypt.

出版信息

BMC Oral Health. 2022 Jun 24;22(1):254. doi: 10.1186/s12903-022-02282-3.

Abstract

BACKGROUND

Debonding of ball attachments is one of the complications that annoy teeth supported overdenture wearers. The polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) polymers are widely applied in the dental field. The purpose of the current study was to compare the tensile bond strength of ball attachments made of such materials and the commonly used titanium ones after 5 years of overdenture insertion and removal (5000 cycles) in addition to chewing simulation (1,200,000 cycle).

METHODS

Extracted mandibular canines (N = 60) were randomly allocated into three groups and received ball attachments; titanium (group TI; N = 20), PEEK (group PE; N = 20), PEKK (group PK; N = 20). In each group, the samples were divided into two subgroups whereas tensile bond strength was measured pre aging (T0; n = 10) and post aging (T1; n = 10). Tensile bond strength was measured by the Pull out test using the Universal testing machine. Failure mode analysis was determined by examination of the samples' surfaces under 65X stereomicroscope. The resulting data followed normal distribution and the significance level was set at (α = 0.05).

RESULTS

One Way Anova showed statistically significant difference between the three groups (P < .00001). PostHoc Tukey test showed statistically significant difference between the groups TI and PE, TI and PK and no statistically significant difference between the groups PE and PK. Paired t test showed statistically significant difference in the tensile bond strength pre and post aging in each group.

CONCLUSIONS

PEEK and PEKK ball attachments could be concluded to have a higher tensile bond strength compared to the titanium ones when bonded to root dentin. Tensile bond strength of such attachments may decrease with aging as well. Clinically, the higher tensile bond strength may have a lesser rate of debonding and thus reduced patient apprehension.

摘要

背景

球附着体的脱粘是困扰义齿修复患者的并发症之一。聚醚醚酮(PEEK)和聚醚酮酮(PEKK)聚合物广泛应用于牙科领域。本研究的目的是比较这些材料制成的球附着体与常用的钛制球附着体在义齿佩戴 5 年后(5000 次循环)以及咀嚼模拟(120 万次循环)后的拉伸结合强度。

方法

从下颌尖牙中随机抽取 60 颗,分为三组并分别植入球附着体;钛组(TI 组,N=20)、PEEK 组(PE 组,N=20)、PEKK 组(PK 组,N=20)。每组样本分为两组,在老化前(T0;n=10)和老化后(T1;n=10)分别测量拉伸结合强度。使用万能试验机进行拉伸结合强度测试。通过在 65X 立体显微镜下检查样品表面来确定失效模式分析。所得数据符合正态分布,显著性水平设为(α=0.05)。

结果

单因素方差分析显示三组间差异具有统计学意义(P<0.00001)。PostHoc Tukey 检验显示 TI 组和 PE 组、TI 组和 PK 组间差异有统计学意义,PE 组和 PK 组间差异无统计学意义。配对 t 检验显示每组的拉伸结合强度在老化前后均有统计学差异。

结论

与钛相比,PEEK 和 PEKK 球附着体与根牙本质结合时具有更高的拉伸结合强度。这种附着体的拉伸结合强度也可能随着老化而降低。临床上,较高的拉伸结合强度可能会降低脱粘率,从而减少患者的担忧。