Suppr超能文献

胫骨干骺端圆锥结合短柄在翻修全膝关节置换术中的表现与长柄一样好。

Tibial metaphyseal cones combined with short stems perform as well as long stems in revision total knee arthroplasty.

机构信息

Department of Medicine, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand.

Department of Orthopaedics, Auckland City Hospital, Auckland, New Zealand.

出版信息

ANZ J Surg. 2022 Sep;92(9):2254-2260. doi: 10.1111/ans.17864. Epub 2022 Jun 27.

Abstract

BACKGROUNDS

There is uncertainty around optimal tibial stem length in revision total knee arthroplasty (rTKA) utilizing a tibial trabecular metal (TM) cone. The purpose of this study was to compare: (1) functional outcomes, (2) radiographic outcomes and (3) implant survivorship in rTKA utilizing TM cones combined with either short stems (SS) or long stems (LS) at minimum 2 years follow-up.

METHODS

In this retrospective, multi-centre study, patients undergoing rTKA utilizing a TM cone between 2008 and 2019 were included. Patients were divided into: SS group (no diaphyseal engagement), and LS group (diaphyseal engagement). All relevant clinical charts and post-operative radiographs were examined. Oxford Knee Score (OKS) and EuroQol-5D (EQ-5D-5L) data were collected at most recent follow-up.

RESULTS

In total, 44 patients were included: 18 in the SS group and 26 in the LS group. The mean time of follow-up was 4.0 years. Failure free survival was 94.4% for the SS group and 92.3% for the LS group. All failures were for prosthetic joint infections managed with debridement, antibiotics, and implant retention. At most recent follow-up, 3 patients demonstrated radiographic signs of lucency (1 SS 2 LS, P = 1) and the mean OKS were 37 ± 4 and 36 ± 6 (P = 0.73) in the SS and LS groups, respectively.

CONCLUSION

Tibial SS combined with TM cones performed as well as LS in rTKA at minimum 2 years follow-up. A tibial SS in combination with a TM cone is a reliable technique to achieve stable and durable fixation in rTKA.

摘要

背景

在使用胫骨小梁金属(TM)锥形物的翻修全膝关节置换术(rTKA)中,胫骨柄的最佳长度存在不确定性。本研究的目的是比较:(1)功能结果,(2)影像学结果和(3)在最低 2 年随访时使用 TM 锥形物结合短柄(SS)或长柄(LS)的 rTKA 的植入物存活率。

方法

在这项回顾性多中心研究中,纳入了 2008 年至 2019 年间接受 TM 锥形物翻修全膝关节置换术的患者。患者分为:SS 组(无骨干接合)和 LS 组(骨干接合)。检查了所有相关的临床图表和术后 X 线片。在最近的随访中收集了牛津膝关节评分(OKS)和欧洲五维健康量表(EQ-5D-5L)数据。

结果

共纳入 44 例患者:SS 组 18 例,LS 组 26 例。平均随访时间为 4.0 年。SS 组的无失败生存率为 94.4%,LS 组为 92.3%。所有失败均为假体关节感染,采用清创术、抗生素和保留植入物治疗。在最近的随访中,有 3 例患者出现透亮线迹象(1 例 SS,2 例 LS,P=1),SS 组和 LS 组的平均 OKS 分别为 37±4 和 36±6(P=0.73)。

结论

胫骨 SS 结合 TM 锥形物在最低 2 年随访时与 LS 一样适用于 rTKA。胫骨 SS 结合 TM 锥形物是一种可靠的技术,可在 rTKA 中实现稳定和持久的固定。