Ahmadi Nemat, Karimian Alireza, Nasrabadi Mehdi Nasri
Faculty of Physics, University of Isfahan, Isfahan, Iran.
Department of Biomedical Engineering, Faculty of Engineering, University of Isfahan, Isfahan, Iran.
J Med Signals Sens. 2022 May 12;12(2):171-175. doi: 10.4103/jmss.JMSS_70_20. eCollection 2022 Apr-Jun.
The purpose of this study is to assess a rare case of fetal radiation absorbed dose here through F-Fludeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) in early pregnancy (5-week-old fetus). The fetal absorbed dose due to the radiation emitted from the mother's body, the fetus self-dose, and the dose received from CT were computed. The 35-year-old patient, weighing 85 kg, was injected with 370 MBq of F-FDG. Imaging started at 1 h with CT acquisition followed by PET imaging. The photon and positron self-dose was calculated by applying the Monte Carlo (MC) GATE (GEANT 4 Application for Tomographic Emission) code. The volume of absorbed dose from the mother's body organs and the absorbed dose from the CT were added to the self-dose to obtain the final dose. The volume of self-dose obtained through MC simulation for the fetus was 3.3 × 10 mGy/MBq, of which 2.97 × 10 mGy/MBq was associated with positrons and 0.33 × 10 mGy/MBq was associated with photons. Biologically, the absorbed dose from CT, 7.3 mGy, had to be added to the total dose. The absorbed dose by the fetus during early pregnancy was higher than the standard value of 2.2 × 10 mGy/MBq (MIRD DER) because, during the examinations, the mother's bladder was full. This issue was a concern during updating standards.
本研究的目的是通过氟脱氧葡萄糖(FDG)正电子发射断层扫描(PET)/计算机断层扫描(CT)评估一例孕早期(5周龄胎儿)胎儿辐射吸收剂量的罕见病例。计算了母亲身体发出的辐射、胎儿自身剂量以及CT所接受的剂量导致的胎儿吸收剂量。该35岁患者体重85kg,注射了370MBq的F-FDG。1小时后开始成像,先进行CT采集,然后进行PET成像。通过应用蒙特卡罗(MC)GATE(用于断层发射的GEANT 4应用程序)代码计算光子和正电子自身剂量。将母亲身体器官的吸收剂量体积和CT的吸收剂量加到自身剂量上,以获得最终剂量。通过MC模拟得到的胎儿自身剂量体积为3.3×10 mGy/MBq,其中2.97×10 mGy/MBq与正电子有关,0.33×10 mGy/MBq与光子有关。从生物学角度看,CT的吸收剂量7.3mGy必须加到总剂量中。孕早期胎儿的吸收剂量高于2.2×10 mGy/MBq(MIRD DER)的标准值,因为在检查期间母亲的膀胱是充盈的。在更新标准时,这个问题令人担忧。