Suppr超能文献

早期妊娠时胎儿吸收的 18F-FDG 剂量。

Absorbed 18F-FDG dose to the fetus during early pregnancy.

机构信息

Nuclear Medicine Department, St Antoine Hospital, Paris, France.

出版信息

J Nucl Med. 2010 May;51(5):803-5. doi: 10.2967/jnumed.109.071878. Epub 2010 Apr 15.

Abstract

UNLABELLED

We describe a rare case of a woman who underwent (18)F-FDG PET/CT during early pregnancy (fetus age, 10 wk). The fetal absorbed dose was calculated by taking into account the (18)F-FDG fetal self-dose, photon dose coming from the maternal tissues, and CT dose received by both mother and fetus.

METHODS

The patient (weight, 71 kg) had received 296 MBq of (18)F-FDG. Imaging started at 1 h, with unenhanced CT acquisition, followed by PET acquisition. From the standardized uptake value measured in fetal tissues, we calculated the total number of disintegrations per unit of injected activity. Monte Carlo analysis was then used to derive the fetal (18)F-FDG self-dose, including positrons and self-absorbed photons. Photon dose from maternal tissues and CT dose were added to obtain the final dose.

RESULTS

The maximum standardized uptake value in fetal tissues was 4.5. Monte Carlo simulation showed that the fetal self-dose was 3.0 x 10(-2) mGy/MBq (2.7 x 10(-2) mGy/MBq from positrons and 0.3 x 10(-2) mGy/MBq from photons). The estimated photon dose to the fetus from maternal tissues was 1.04 x 10(-2) mGy/MBq. Accordingly, the specific (18)F-FDG dose to the fetus was about 4.0 x 10(-2) mGy/MBq (11.8 mGy in this patient). The CT scan added a further 10 mGy.

CONCLUSION

The dose to the fetus during early pregnancy can be as high as 4.0 x 10(-2) mGy/MBq of (18)F-FDG. Current dosimetric standards in early pregnancy may need to be revised.

摘要

未加标签

我们描述了一例罕见的孕妇在孕早期进行(18)F-FDG PET/CT 的病例(胎儿年龄为 10 周)。胎儿吸收剂量通过考虑(18)F-FDG 胎儿自吸收剂量、来自母体组织的光子剂量以及母亲和胎儿接受的 CT 剂量来计算。

方法

患者(体重 71kg)接受了 296MBq 的(18)F-FDG。成像在 1 小时时开始,进行非增强 CT 采集,随后进行 PET 采集。从胎儿组织中测量的标准化摄取值,我们计算了单位注入活度的放射性衰变总数。然后使用蒙特卡罗分析来推导胎儿(18)F-FDG 自吸收剂量,包括正电子和自吸收光子。将来自母体组织的光子剂量和 CT 剂量相加,以获得最终剂量。

结果

胎儿组织中的最大标准化摄取值为 4.5。蒙特卡罗模拟表明,胎儿自吸收剂量为 3.0×10(-2)mGy/MBq(正电子为 2.7×10(-2)mGy/MBq,光子为 0.3×10(-2)mGy/MBq)。来自母体组织的胎儿光子剂量估计为 1.04×10(-2)mGy/MBq。因此,胎儿接受的特定(18)F-FDG 剂量约为 4.0×10(-2)mGy/MBq(在该患者中为 11.8mGy)。CT 扫描增加了另外 10mGy。

结论

在孕早期,胎儿接受的剂量高达 4.0×10(-2)mGy/MBq 的(18)F-FDG。目前在孕早期的剂量学标准可能需要修订。