Suppr超能文献

两种自动化鉴定/药敏试验系统与Mikrolatest试剂盒在评估耐碳青霉烯类肠杆菌科分离株对黏菌素敏感性方面的比较评价:一项来自印度北部的单中心探索性研究

Comparative Evaluation of Two Automated ID/AST Systems and Mikrolatest Kit in Assessing the Colistin Susceptibility of Carbapenem-Resistant Enterobacteriaceae Isolates: A Single-Center Exploratory Study from North India.

作者信息

Bhatia Mohit, Singh Ravi Indrapal, Rani Diksha, Rekha U Sasi, Rohilla Ranjana, Omar Balram Ji, Gupta Pratima

机构信息

Department of Microbiology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India.

Department of Microbiology, Sri Guru Ram Rai Institute of Medical and Health Sciences, Dehradun, Uttarakhand, India.

出版信息

J Pharm Bioallied Sci. 2022 Jan-Mar;14(1):52-55. doi: 10.4103/jpbs.jpbs_651_21. Epub 2022 May 19.

Abstract

AIMS

To generate preliminary data about comparative evaluation of two automated ID/AST systems and Mikrolatest kit in determining colistin susceptibility of carbapenem-resistant spp.

MATERIALS AND METHODS

Twenty-three carbapenem-resistant and and two carbapenem-sensitive multidrug-resistant isolates obtained from various clinical samples of inpatients were included in the study. Species-level identification and antibiotic susceptibility testing (AST) of test isolates was performed using BD phoenix and MicroScan WalkAway 96 Plus automated systems. Identity was reconfirmed by matrix-assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI-TOF MS). Additional colistin susceptibility testing was performed using Mikrolatest MIC colistin susceptibility testing kit (reference method).

RESULTS

Results showed that 16% isolates (27.3% [3/11] and 7.1% [1/14] ) exhibited colistin resistance by the reference method. While the categorical agreement between BD Phoenix M50 ID/AST system and reference test w. r. t colistin susceptibility results was 100% and 92.9% for & , respectively, it was much lower between MicroScan WalkAway 96 plus ID/AST system and the latter. Almost perfect agreement (96%; kappa: 0.834) was observed between BD Phoenix M50 system and reference method.

CONCLUSIONS

The results of this study are preliminary and cannot be generalized. Multicentric studies with large sample sizes should be conducted throughout the country to gain a deeper understanding of the subject under consideration.

摘要

目的

生成关于两种自动化鉴定/药敏试验(ID/AST)系统与Mikrolatest试剂盒在确定耐碳青霉烯类菌株对黏菌素敏感性方面的比较评估的初步数据。

材料与方法

本研究纳入了从住院患者的各种临床样本中分离出的23株耐碳青霉烯类菌株和2株耐多药且对碳青霉烯类敏感的菌株。使用BD phoenix和MicroScan WalkAway 96 Plus自动化系统对测试菌株进行菌种水平鉴定和抗生素敏感性试验(AST)。通过基质辅助激光解吸电离飞行时间质谱(MALDI-TOF MS)再次确认菌株身份。使用Mikrolatest MIC黏菌素敏感性试验试剂盒(参考方法)进行额外的黏菌素敏感性试验。

结果

结果显示,通过参考方法,16%的菌株(分别为27.3%[3/11]和7.1%[1/14])表现出对黏菌素耐药。BD Phoenix M50 ID/AST系统与参考试验在黏菌素敏感性结果方面的分类一致性分别为100%和92.9%,而MicroScan WalkAway 96 plus ID/AST系统与后者之间的一致性则低得多。BD Phoenix M50系统与参考方法之间观察到几乎完美的一致性(96%;kappa值:0.834)。

结论

本研究结果是初步的,不能一概而论。应在全国范围内开展大样本量的多中心研究,以更深入地了解所研究的主题。

相似文献

6
Multicenter study of automated systems for colistin susceptibility testing.
Eur J Clin Microbiol Infect Dis. 2021 Mar;40(3):575-579. doi: 10.1007/s10096-020-04059-4. Epub 2020 Oct 6.
9

本文引用的文献

3
Epidemiology of β-Lactamase-Producing Pathogens.
Clin Microbiol Rev. 2020 Feb 26;33(2). doi: 10.1128/CMR.00047-19. Print 2020 Mar 18.
5
7
Statistical analysis of microbiological diagnostic tests.
Indian J Med Microbiol. 2017 Apr-Jun;35(2):184-193. doi: 10.4103/ijmm.IJMM_16_215.
8
Carbapenem resistant Klebsiella pneumoniae isolated from bloodstream infection: Indian experience.
Pathog Glob Health. 2017 Jul;111(5):240-246. doi: 10.1080/20477724.2017.1340128. Epub 2017 Jul 2.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验