CT measurement of prostate volume using OsiriX viewer is reliable, repeatable, and not dependent on observer, CT protocol, or contrast enhancement in dogs.

机构信息

Department of Equine and Small Animal Medicine, Faculty of Veterinary Medicine, University of Helsinki, Helsinki, Finland.

出版信息

Vet Radiol Ultrasound. 2022 Nov;63(6):729-738. doi: 10.1111/vru.13125. Epub 2022 Jul 5.

Abstract

Computed tomography (CT) is an established method for evaluating dogs with suspected prostatic disease; however, publications assessing the effects of varying factors on prostate volume measurements are lacking. The objectives of this two-part, observer agreement, methods comparison study were to assess observer agreement and the effects of varying CT technical parameters for volume measurements of canine prostate glands on CT images using OsiriX DICOM viewer software. In the first retrospective study, two observers measured prostate volumes of 13 client-owned dogs thrice on noncontrast and contrast CT images. In the second prospective study, two observers measured the prostate volume of 10 cadavers using five different CT protocols and eight cadavers using three slice thicknesses. Observer agreement analyses were performed, and prostatic CT volume measurements were compared with water displacement volume measurements. Intra- and interobserver variability and the effect of contrast enhancement were found to be minimal when a one-way analysis of variance model and intraclass correlation coefficients were used. No significant differences emerged between different protocols and slice thicknesses using a linear mixed effects model. When the prostate CT volume was compared using a Bland-Altman plot with the reference volume acquired by the water displacement method, agreement without consistent bias between the methods was shown, and over 90% of measurements were located within the 95% limits of agreement. The findings supported using OsiriX software for CT prostatic volume measurements in dogs.

摘要

计算机断层扫描(CT)是评估疑似前列腺疾病犬的一种既定方法;然而,评估各种因素对前列腺体积测量影响的出版物却很少。本项两部分、观察者一致性、方法比较研究的目的是使用 OsiriX DICOM 查看器软件评估观察者一致性,以及不同 CT 技术参数对 CT 图像中犬前列腺体积测量的影响。在第一项回顾性研究中,两名观察者在非增强和增强 CT 图像上对 13 只患犬的前列腺体积进行了三次测量。在第二项前瞻性研究中,两名观察者使用五种不同的 CT 协议和三种切片厚度对 10 具尸体的前列腺体积进行了测量。进行了观察者一致性分析,并将前列腺 CT 体积测量值与水置换体积测量值进行了比较。使用单向方差分析模型和组内相关系数时,发现当增强时,观察者内和观察者间的可变性以及增强的效果最小。使用线性混合效应模型时,不同的协议和切片厚度之间没有出现显著差异。当使用 Bland-Altman 图将前列腺 CT 体积与水置换法获得的参考体积进行比较时,显示出两种方法之间没有一致偏差的一致性,超过 90%的测量值位于 95%一致性界限内。这些发现支持在犬中使用 OsiriX 软件进行 CT 前列腺体积测量。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/abd7/9795897/b2bbdeb103d2/VRU-63-729-g004.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验