Suppr超能文献

摩洛哥阿加迪尔哈桑二世医院 CT 扫描成像的辐射剂量。

Radiation doses during computed tomography scan imaging in Hassan II Hospital, Agadir, Morocco.

机构信息

Higher Institute of Nursing Professions and Health Techniques, Agadir, Morocco.

Faculty of Medicine and Pharmacy, Ibn Zohr University of Agadir, Agadir, Morocco.

出版信息

Pan Afr Med J. 2022 Apr 11;41:290. doi: 10.11604/pamj.2022.41.290.25090. eCollection 2022.

Abstract

INTRODUCTION

the aim of this study was to establish local Diagnostic Reference Levels (DRLs) for four adult Computed Tomography (CT) examinations in the radiology department, Hassan II hospital of Agadir.

METHODS

during this survey, we have examined the data of 200 patients at an average of 50 per localization. A General Electric 16 CT with automatic exposure control system was used to perform all CT examinations. Scanner acquisition parameters, number of series, contrast medium use, rotation time plus slice thickness, the displayed Computed Tomography Dose Index (CTDI), and the Dose Length Product (DLP) were among the data collected for each diagnostic exam chosen. To evaluate the DRL and effective dose, the conversion factor and formalism of the International Commission on Radiological Protection (ICRP) were utilized.

RESULTS

the average effective dose (Eeff), the displayed CT dose index (CTDI), dose length product (DLP) were (7.28±2.35) mSv, (10.80±3.80) mGy and (428.35±138.26) mGy.cm respectively at chest CT. For abdomen-pelvis CT scan, there were (12.48±5.58) mSv, (9.30±2.99) mGy and (805.43±359.98) mGy. Those at chest abdomen-pelvic CT scan were (11.72±3.98) mSv, (10.82±2.53) mGy and (755.97±251.52) mGy.cm respectively. For lumbar CT, there were (12.12±2.32) mSv, (26.46±5.24) mGy and (787.00±149.37) mGy.cm respectively.

CONCLUSION

the findings of this study shows that our values are slightly higher than those of developed countries. This first-ever CT practice evaluation at Agadir's Hassan II Hospital reinforced the need for further radiology training for computed tomography practitioners on parameters influencing image quality, dose, and protocols improvement.

摘要

简介

本研究旨在为阿加迪尔哈桑二世医院放射科的四项成人 CT 检查建立当地诊断参考水平(DRL)。

方法

在这项调查中,我们对 200 名平均每个部位 50 名患者的数据进行了检查。使用具有自动曝光控制系统的通用电气 16 CT 对所有 CT 检查进行了检查。收集的每个诊断检查数据包括扫描采集参数、序列数量、造影剂使用、旋转时间加切片厚度、显示的 CT 剂量指数(CTDI)和剂量长度乘积(DLP)。为了评估 DRL 和有效剂量,使用了国际辐射防护委员会(ICRP)的转换因子和形式。

结果

胸部 CT 的平均有效剂量(Eeff)、显示的 CT 剂量指数(CTDI)和剂量长度乘积(DLP)分别为(7.28±2.35)mSv、(10.80±3.80)mGy 和(428.35±138.26)mGy·cm。腹部-骨盆 CT 扫描的分别为(12.48±5.58)mSv、(9.30±2.99)mGy 和(805.43±359.98)mGy·cm。胸部-腹部-骨盆 CT 扫描的分别为(11.72±3.98)mSv、(10.82±2.53)mGy 和(755.97±251.52)mGy·cm。腰椎 CT 的分别为(12.12±2.32)mSv、(26.46±5.24)mGy 和(787.00±149.37)mGy·cm。

结论

本研究的结果表明,我们的数值略高于发达国家。这是阿加迪尔哈桑二世医院首次对 CT 实践进行评估,这加强了对 CT 从业人员进行影响图像质量、剂量和协议改进的参数进一步培训的必要性。

相似文献

1
Radiation doses during computed tomography scan imaging in Hassan II Hospital, Agadir, Morocco.
Pan Afr Med J. 2022 Apr 11;41:290. doi: 10.11604/pamj.2022.41.290.25090. eCollection 2022.
3
Establishment of a local diagnostic reference level for computed tomography chest and abdomen in two different cities in Saudi Arabia.
Appl Radiat Isot. 2024 Feb;204:111147. doi: 10.1016/j.apradiso.2023.111147. Epub 2023 Dec 14.
4
5
Establishment of local diagnostic reference levels for computed tomography with cloud-based automated dose-tracking software in Türkiye.
Diagn Interv Radiol. 2024 May 13;30(3):205-211. doi: 10.4274/dir.2023.232265. Epub 2023 Aug 31.
6
Radiation doses from head, neck, chest and abdominal CT examinations: an institutional dose report.
Diagn Interv Radiol. 2021 Jan;27(1):147-151. doi: 10.5152/dir.2020.19560.
7
Assessment of paediatric CT dose indicators for the purpose of optimisation.
Br J Radiol. 2012 Nov;85(1019):1488-98. doi: 10.1259/bjr/28015185. Epub 2012 Jul 27.
8
Application of European Commission reference dose levels in CT examinations in Crete, Greece.
Br J Radiol. 2001 Sep;74(885):836-40. doi: 10.1259/bjr.74.885.740836.

本文引用的文献

1
Multisection computed tomography: Results from a Chinese survey on radiation dose metrics.
J Chin Med Assoc. 2019 Feb;82(2):155-160. doi: 10.1097/JCMA.0000000000000019.
2
Establishment of diagnostic reference levels for CT trunk examinations in the western region of Saudi Arabia.
Radiat Prot Dosimetry. 2015 Dec;167(4):569-75. doi: 10.1093/rpd/ncu343. Epub 2014 Dec 2.
3
[Results of the Austrian CT dose study 2010: typical effective doses of the most frequent CT examinations].
Z Med Phys. 2014 Sep;24(3):224-30. doi: 10.1016/j.zemedi.2013.12.005. Epub 2014 Jan 17.
5
French diagnostic reference levels in diagnostic radiology, computed tomography and nuclear medicine: 2004-2008 review.
Radiat Prot Dosimetry. 2013 Apr;154(1):52-75. doi: 10.1093/rpd/ncs152. Epub 2012 Sep 6.
6
Establishment of CT diagnostic reference levels in Ireland.
Br J Radiol. 2012 Oct;85(1018):1390-7. doi: 10.1259/bjr/15839549. Epub 2012 May 17.
7
Patient doses in CT examinations in Switzerland: implementation of national diagnostic reference levels.
Radiat Prot Dosimetry. 2010 Dec;142(2-4):244-54. doi: 10.1093/rpd/ncq279. Epub 2010 Oct 6.
8
Survey of computed tomography doses and establishment of national diagnostic reference levels in the Republic of Belarus.
Radiat Prot Dosimetry. 2010 Apr-May;139(1-3):367-70. doi: 10.1093/rpd/ncq070. Epub 2010 Feb 24.
10
Towards establishment of the national reference dose levels from computed tomography examinations in Tanzania.
J Radiol Prot. 2006 Jun;26(2):213-25. doi: 10.1088/0952-4746/26/2/006. Epub 2006 May 26.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验