Suppr超能文献

多层螺旋 CT:中国辐射剂量学指标调查结果。

Multisection computed tomography: Results from a Chinese survey on radiation dose metrics.

机构信息

Department of Radiology, The First Hospital of Jilin University, Changchun, China.

Department of Clinical Epidemiology, The First Hospital of Jilin University, Changchun, China.

出版信息

J Chin Med Assoc. 2019 Feb;82(2):155-160. doi: 10.1097/JCMA.0000000000000019.

Abstract

BACKGROUND

As multisection spiral computed tomography (MSCT) have been extensively used, it is important to consider the amounts of doses the patients are exposed during a computed tomography (CT) examination. The aim of the current study was to summarize MSCT doses in Chinese patients to establish the diagnostic reference levels (DRLs).

METHODS

Radiation dose metrics were retrospectively collected from 164,073 CT examinations via the Radimetrics Enterprise Platform. Radiation dose metrics (volume CT dose index [CTDIvol], dose-length product [DLP], effective dose [ED], and organ dose) and size-specific dose estimate (SSDE) were calculated for adults and children based on anatomic area and scanner type.

RESULTS

The median CTDIvol and DLP values were highest in the head at 51.7 mGy (interquartile range [IQR], 33.2-51.7 mGy) and 906.5 mGy·cm (IQR, 582.4-1068.2 mGy·cm) and lowest in the chest at 7.9 mGy (IQR, 7.9-10.3 mGy) and 284.8 mGy·cm (IQR, 249.0-412.6 mGy·cm), respectively. The median SSDE values of chest and pelvis were 12.1 mGy (IQR, 10.8-14.1 mGy) and 36.3 mGy (IQR, 34.0-38.9 mGy), respectively. EDs for children were similar to adults except for an increased 1.5-, 0.77-, and 1.7-fold in the chest, neck, and pelvis, respectively (p < 0.001). Furthermore, radiation doses tended to increase with increasing slice number and decrease when exposure reduction techniques were used.

CONCLUSION

Our findings provide a basis for the evaluation of CT radiation doses and evidence for establishment of DRLs in China.

摘要

背景

随着多排螺旋 CT(MSCT)的广泛应用,考虑患者在 CT 检查中所接受的剂量变得尤为重要。本研究旨在总结中国患者的 MSCT 剂量,以建立诊断参考水平(DRLs)。

方法

通过 Radimetrics 企业平台回顾性收集了 164073 例 CT 检查的辐射剂量指标。根据解剖区域和扫描仪类型,为成人和儿童计算了辐射剂量指标(容积 CT 剂量指数[CTDIvol]、剂量长度乘积[DLP]、有效剂量[ED]和器官剂量)和大小特异性剂量估计值(SSDE)。

结果

头部的 CTDIvol 和 DLP 中位数最高,分别为 51.7 mGy(四分位距[IQR],33.2-51.7 mGy)和 906.5 mGy·cm(IQR,582.4-1068.2 mGy·cm),胸部最低,分别为 7.9 mGy(IQR,7.9-10.3 mGy)和 284.8 mGy·cm(IQR,249.0-412.6 mGy·cm)。胸部和骨盆的 SSDE 中位数分别为 12.1 mGy(IQR,10.8-14.1 mGy)和 36.3 mGy(IQR,34.0-38.9 mGy)。除胸部、颈部和骨盆的 ED 分别增加 1.5 倍、0.77 倍和 1.7 倍外,儿童的 ED 与成人相似(p < 0.001)。此外,随着切片数量的增加,辐射剂量趋于增加,而当使用降低辐射剂量技术时,辐射剂量则降低。

结论

本研究结果为评估 CT 辐射剂量提供了依据,并为中国建立 DRLs 提供了证据。