Poliner L S, Grand M G, Schoch L H, Olk R J, Johnston G P, Okun E, Boniuk I, Escoffery R F
Ophthalmology. 1987 Apr;94(4):315-8. doi: 10.1016/s0161-6420(87)33445-1.
Thirteen cases of rhegmatogenous retinal detachment repaired by pneumatic retinopexy were reviewed retrospectively. All patients were followed for a minimum of 6 months after surgery. At the end of follow-up, retinal detachment repair by pneumatic retinopexy succeeded in nine cases (70%) and failed in four (30%). Within 2 days of pneumatic retinopexy, vitreous condensation and traction with new retinal tears and associated detachments in previously uninvolved quadrants developed in two patients. The occurrence of new retinal detachments in the early postoperative period after pneumatic retinopexy has not been previously observed.
回顾性分析了13例采用气体视网膜固定术修复的孔源性视网膜脱离病例。所有患者术后至少随访6个月。随访结束时,气体视网膜固定术修复视网膜脱离成功9例(70%),失败4例(30%)。在气体视网膜固定术后2天内,2例患者出现玻璃体浓缩、牵引以及新的视网膜裂孔和先前未受累象限的相关脱离。气体视网膜固定术后早期出现新的视网膜脱离情况此前未见报道。