Suppr超能文献

一种用于胃癌(G17 和 CA724 双标记时间分辨荧光免疫分析)早期筛查的新方法。

A New Method for Early Screening of Gastric Cancer (G17 and CA724 Dual-Labeled Time-Resolved Fluorescence Immunoassay).

机构信息

Heilongjiang Academy of Chinese Medicine Sciences, Harbin, 150036, China.

Guangzhou Youdi Bio-Technology Co., Ltd., Guangzhou 510663, China.

出版信息

Comput Math Methods Med. 2022 Jul 20;2022:1704948. doi: 10.1155/2022/1704948. eCollection 2022.

Abstract

Gastric carcinoma (GC) is one of the most common malignancies in the world with the great early screening challenges. The study is aimed at establishing a new detection method for early screening GC using time-resolved fluorescence immunoassay (TRFIA) via quantitative detection of gastrin-17 (G-17) and carbohydrate antigen 724 (CA724) in serum. Time-resolved analyzer measured the fluorescence intensity. The standards of G-17/CA724 were used for drawing the standard curve, which is used to calculate the concentration of G-17 and CA724 in serum sample. The sensitivity for G-17 was 0.54 pg/mL and for CA724 was 0.28 U/mL with a wide-range analyze concentration (0.1-1000) pg/mL or U/mL. The average recoveries ranged from 100.52% to 110.30% for G-17 and 103.02% to 116.00% for CA724. All CVs of the intra- and interassay were below 10% with high specificity. There was a high coefficient between this TRFIA method and the commercially available kits (Pearson 0.9117 for G-17 and 0.9449 for CA724). Additionally, the cutoff value was 88.41 pg/mL and 5.47 U/mL for CA724 in health subjects. This study established a TRFIA method for simultaneous detection of the concentrations of G-17 and CA724 in serum, which provide a new method for sensitive, accurate, and specific early screening of gastric cancer.

摘要

胃癌(GC)是世界上最常见的恶性肿瘤之一,早期筛查极具挑战性。本研究旨在通过定量检测血清胃泌素-17(G-17)和糖类抗原 724(CA724),建立一种新的用于早期筛查 GC 的检测方法。时间分辨荧光免疫分析(TRFIA)采用时间分辨分析仪测量荧光强度。使用 G-17/CA724 标准品绘制标准曲线,用于计算血清样本中 G-17 和 CA724 的浓度。G-17 的检测灵敏度为 0.54 pg/mL,CA724 的检测灵敏度为 0.28 U/mL,分析浓度范围(0.1-1000)pg/mL 或 U/mL。G-17 的平均回收率在 100.52%至 110.30%之间,CA724 的平均回收率在 103.02%至 116.00%之间。G-17 和 CA724 的批内和批间 CV 均低于 10%,具有高度特异性。该 TRFIA 方法与市售试剂盒之间具有高度相关性(G-17 的 Pearson 相关系数为 0.9117,CA724 的 Pearson 相关系数为 0.9449)。此外,健康受试者的 CA724 截断值为 88.41 pg/mL 和 5.47 U/mL。本研究建立了一种同时检测血清中 G-17 和 CA724 浓度的 TRFIA 方法,为胃癌的敏感、准确、特异性早期筛查提供了一种新方法。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/42e7/9328981/c083b21d851c/CMMM2022-1704948.001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验