Suppr超能文献

应用意向性面神经刺激在人工耳蜗植入术中作为一种电生理工具,以评估耳蜗内电极位置。

Application of intentional facial nerve stimulation during cochlear implantation as an electrophysiological tool to estimate the intracochlear electrode position.

机构信息

Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Josef-Schneider-Str. 11, 97080, Wuerzburg, Germany.

Department of Diagnostic and Interventional Neuroradiology, University of Wuerzburg, Josef-Schneider-Str. 11, 97080, Wuerzburg, Germany.

出版信息

Sci Rep. 2022 Aug 4;12(1):13426. doi: 10.1038/s41598-022-17732-9.

Abstract

This proof of concept describes the use of evoked electromyographic (EMG) activation of the facial nerve for intraoperative monitoring of the electrode insertion during cochlear implantation (CI). Intraoperative EMG measurements from the facial nerve were conducted in nine patients undergoing CI implantation. Electric current pulses were emitted from contacts on the CI array during and immediately after electrode insertion. For control, the results of EMG measurements were compared to postoperative flat panel volume computed tomography scans with secondary reconstruction (fpVCT). During insertion, the EMG response evoked by the electrical stimulation from the CI was growing with the stimulating contact approaching the facial nerve and declined with increasing distance. After full insertion, contacts on the apical half of the CI array stimulated higher EMG responses compared with those on the basal half. Comparison with postoperative imaging demonstrated that electrode contacts stimulating high EMG responses had the shortest distances to the facial nerve. It could be demonstrated that electrically evoked EMG activation of the facial nerve can be used to monitor the progress during CI electrode insertion and to control the intracochlear electrode position after full insertion.

摘要

本概念验证描述了在人工耳蜗植入 (CI) 过程中使用诱发肌电图 (EMG) 对面神经进行激活,以实现对电极插入过程的术中监测。在接受 CI 植入的 9 名患者中进行了面神经的术中 EMG 测量。在电极插入过程中和插入后立即,从 CI 阵列上的接触点发出电流脉冲。作为对照,将 EMG 测量结果与术后平板容积 CT 扫描(带二次重建)(fpVCT)进行比较。在插入过程中,CI 发出的电刺激引起的 EMG 反应随着刺激接触点接近面神经而增加,并随着距离的增加而减少。完全插入后,CI 阵列的尖端部分的接触点刺激产生的 EMG 反应高于基底部的接触点。与术后影像学比较表明,刺激产生高 EMG 反应的电极接触点与面神经的距离最短。可以证明,电诱发面神经 EMG 激活可用于监测 CI 电极插入过程中的进展,并在完全插入后控制内耳蜗电极位置。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/85dc/9352782/fb70a359615c/41598_2022_17732_Fig1_HTML.jpg