Environ Sci Pollut Res Int. 2023 Jan;30(2):3112-3120. doi: 10.1007/s11356-022-22432-y. Epub 2022 Aug 9.
Thermo-mineral springs are widely spread over the volcanic areas of Salerno, a city in southern Italy. Although the water of thermal structures provides beneficial effects on human health, the air is characterized by the presence of potentially toxic compounds, such as hydrogen sulphide (HS) and sulphur dioxide (SO). Exposure to sulphurous compounds may have detrimental effects on human health, with asthma being the most common. In this study, air concentrations of HS and SO in the thermal springs of Contursi Terme (Salerno, Italy) were monitored for 4 months (using both active and passive sampling), along with the chemical and microclimatic characterization of thermal water, to assess workers' exposure to these pollutants. An in-depth characterization of indoor air at the springs is paramount to establish emission control limits for occupational exposure and to take protective measures. The air concentration of SO varied from 0.11 ± 0.02 to 0.91 ± 0.02 mg/m, following a seasonal pattern (higher values in winter and lower in spring). Conversely, indoor HS concentrations did not vary significantly with time, but outdoor levels (from 0.40 ± 0.03 to 1.90 ± 0.03 mg/m) were always higher than indoor ones (from 0.11 ± 0.03 to 0.56 ± 0.03 mg/m). Not negligible air concentrations of these pollutants were detected in this thermal spring workplace, so further investigations are needed to ensure workers' safety.
热矿泉广泛分布于意大利南部城市萨莱诺的火山地区。尽管热结构中的水对人体健康有益,但空气中的特点是存在潜在的有毒化合物,如硫化氢 (HS) 和二氧化硫 (SO)。接触含硫化合物可能对人体健康造成不利影响,其中哮喘最为常见。在这项研究中,监测了意大利萨莱诺孔图尔西泰尔梅(Contursi Terme)热泉的 HS 和 SO 空气浓度(使用主动和被动采样),以及热泉水的化学和小气候特征,以评估工人接触这些污染物的情况。对温泉室内空气进行深入的特征描述对于确定职业暴露的排放控制限值和采取保护措施至关重要。SO 的空气浓度呈现季节性变化,范围为 0.11 ± 0.02 至 0.91 ± 0.02 mg/m(冬季较高,春季较低)。相反,室内 HS 浓度随时间变化不大,但室外水平(0.40 ± 0.03 至 1.90 ± 0.03 mg/m)始终高于室内水平(0.11 ± 0.03 至 0.56 ± 0.03 mg/m)。在这个温泉工作场所检测到这些污染物的空气浓度不可忽视,因此需要进一步调查以确保工人的安全。