Abstract

The gold standard for pediatric chest imaging remains the CT scan. An ideal pediatric chest CT has the lowest radiation dose with the least motion degradation possible in a diagnostic scan. Because of the known inherent risks and costs of anesthesia, non-sedate options are preferred. Dual-source CTs are currently the fastest, lowest-dose CT scanners available, utilizing an ultra-high-pitch mode resulting in sub-second CTs. The dual-energy technique, available on dual-source CT scanners, gathers additional information such as pulmonary blood volume and includes relative contrast enhancement and metallic artifact reduction, features that are not available in high-pitch flash mode. In this article we discuss the benefits and tradeoffs of dual-source CT scan modes and tips on image optimization.

摘要

儿科胸部成像的金标准仍然是 CT 扫描。理想的儿科胸部 CT 应具有最低的辐射剂量和尽可能少的运动伪影,以获得诊断性扫描。由于已知存在麻醉的固有风险和成本,因此首选非镇静选项。双源 CT 是目前最快、剂量最低的 CT 扫描仪,采用超高帧率模式,可在亚秒级完成 CT 扫描。双能技术可在双源 CT 扫描仪上获得,可收集额外的信息,如肺血量,并包括相对对比增强和减少金属伪影,这些都是高帧率闪光模式所不具备的功能。本文讨论了双源 CT 扫描模式的优缺点以及图像优化技巧。