Suppr超能文献

病毒载量可能会影响鼻拭子在用于检测严重急性呼吸综合征冠状病毒2(SARS-CoV-2)的核酸扩增试验和定量抗原试验中的诊断性能。

Viral load may impact the diagnostic performance of nasal swabs in nucleic acid amplification test and quantitative antigen test for SARS-CoV-2 detection.

作者信息

Fujiya Yoshihiro, Sato Yuki, Katayama Yuki, Nirasawa Shinya, Moriai Mikako, Saeki Masachika, Yakuwa Yuki, Kitayama Ikumi, Asanuma Koichi, Kuronuma Koji, Takahashi Satoshi

机构信息

Department of Infection Control and Laboratory Medicine, Sapporo Medical University School of Medicine, Japan.

Division of Laboratory Medicine, Sapporo Medical University Hospital, Japan.

出版信息

J Infect Chemother. 2022 Nov;28(11):1590-1593. doi: 10.1016/j.jiac.2022.07.023. Epub 2022 Aug 8.

Abstract

INTRODUCTION

Compared to nasopharyngeal swabs (NPS), there has been insufficient evaluation of the diagnostic performance of nasal swabs (NS) for the detection of severe acute respiratory coronavirus 2 (SARS-CoV-2) in the nucleic acid amplification test (NAAT) and quantitative SARS-CoV-2 antigen test (QAT).

METHODS

We prospectively compared healthcare worker-collected and flocked NS within nine days after symptom onset to paired NPS to detect SARS-CoV-2 in NAAT and QAT on the fully automated Lumipulse system. The agreement between sample types was evaluated, and cycle threshold (Ct) values and antigen levels were used as surrogate viral load measures.

RESULTS

Sixty sets of NPS and NS samples were collected from 40 patients with COVID-19. The overall agreements between NAAT and QAT samples were 76.7% and 65.0%, respectively. In NAAT, the Ct value of NS was significantly higher, 5.9, than that of NPS. Thirty-nine (95.1%) NS tested positive in 41 positive-paired NPS with Ct ≤ 30. The negative correlation was observed between antigen levels of NS in QAT and Ct values of NS in NAAT (r = -0.88). In QAT, the antigen level of NS was significantly lower than that of NPS. Thirty-six (90.0%) NS tested positive in 40 positive-paired NPS with antigen levels >100 pg/mL, which were collected significantly earlier than those with antigen levels ≤100 pg/mL.

CONCLUSIONS

In NAAT and QAT, NS had limited performance in detecting SARS-CoV-2 compared to NPS. However, NS may be helpful for patients with COVID-19 with high viral loads or those in the early stages of the illness.

摘要

引言

与鼻咽拭子(NPS)相比,对于鼻拭子(NS)在核酸扩增试验(NAAT)和定量严重急性呼吸综合征冠状病毒2(SARS-CoV-2)抗原检测(QAT)中检测SARS-CoV-2的诊断性能评估不足。

方法

我们前瞻性地比较了症状出现后9天内医护人员采集的植绒鼻拭子与配对的鼻咽拭子,以在全自动Lumipulse系统上通过NAAT和QAT检测SARS-CoV-2。评估了样本类型之间的一致性,并将循环阈值(Ct)值和抗原水平用作替代病毒载量指标。

结果

从40例新冠肺炎患者中收集了60组鼻咽拭子和鼻拭子样本。NAAT和QAT样本之间的总体一致性分别为76.7%和65.0%。在NAAT中,鼻拭子的Ct值显著高于鼻咽拭子,为5.9。在41对Ct≤30的阳性配对鼻咽拭子中,39份(95.1%)鼻拭子检测呈阳性。在QAT中,鼻拭子的抗原水平与NAAT中鼻拭子的Ct值之间存在负相关(r=-0.88)。在QAT中,鼻拭子的抗原水平显著低于鼻咽拭子。在40对抗原水平>100 pg/mL的阳性配对鼻咽拭子中,36份(90.0%)鼻拭子检测呈阳性,这些样本的采集时间明显早于抗原水平≤100 pg/mL的样本。

结论

在NAAT和QAT中,与鼻咽拭子相比,鼻拭子在检测SARS-CoV-2方面性能有限。然而,鼻拭子可能有助于病毒载量高的新冠肺炎患者或疾病早期患者。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0cd0/9359764/b0aa218006b2/gr1_lrg.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验