Suppr超能文献

哮喘成人的 Glittre-ADL 测试的有效性和可靠性。

Validity and reliability of the Glittre-ADL test in adults with asthma.

机构信息

Graduate Program in Rehabilitation Sciences, Pitágoras-Unopar University (UNOPAR), Paraná, Brasil.

Laboratory of Research in Respiratory Physiotherapy - LFIP, Department of Physiotherapy, Londrina State University, Londrina, Brazil.

出版信息

Physiother Theory Pract. 2023 May;39(5):1052-1060. doi: 10.1080/09593985.2022.2114301. Epub 2022 Aug 27.

Abstract

INTRODUCTION

Adults with asthma may have limitations in their activities of daily living (ADL) and among the most used tests to assess ADL, performance-based instruments such as the Glittre-Activities of Daily Living (Glittre-ADL) test are available. However, metric properties of this instrument have not yet been investigated in this population.

OBJECTIVE

To verify the construct validity and reliability of the Glittre-ADL test in adults with asthma.

METHODS

Fifty-eight adults with asthma had their ADL objectively assessed by Glittre-ADL test, which was performed twice by the same rater. Lung function (spirometry), functional exercise capacity (6-minute walk test, 6MWT), and quality of life (St George's Respiratory Questionnaire, SGRQ) were also assessed.

RESULTS

Participants were 31% men; 43 ± 14 years; FEV1 74 ± 18% predicted. Performance in the Glittre-ADL test correlated with the 6MWT (r = -0.61; P < .0001) and had excellent intraclass correlation coefficient ICC = 0.95. Standard error of measurement was 23%, and the minimal detectable change was 29 seconds. Furthermore, the learning effect was 11 seconds (5.03%).

CONCLUSION

The Glittre-ADL test is valid and reliable for assessing ADL in adults with asthma. However, considerable learning effect was observed and therefore the best of two measures can avoid underestimation.

摘要

简介

成年人哮喘可能会限制他们的日常生活活动(ADL),而在评估 ADL 的最常用测试中,有基于表现的测试,例如 Glittre-日常生活活动(Glittre-ADL)测试。然而,该仪器的度量特性尚未在该人群中进行研究。

目的

验证 Glittre-ADL 测试在哮喘成人中的结构有效性和可靠性。

方法

58 名哮喘成年人通过 Glittre-ADL 测试客观评估他们的 ADL,由同一位评估者进行两次测试。还评估了肺功能(肺活量测定法)、功能性运动能力(6 分钟步行测试,6MWT)和生活质量(圣乔治呼吸问卷,SGRQ)。

结果

参与者中 31%为男性;43±14 岁;FEV1 为预计值的 74±18%。Glittre-ADL 测试的表现与 6MWT 相关(r=-0.61;P<.0001),且具有极好的组内相关系数 ICC=0.95。测量标准误差为 23%,最小可检测变化为 29 秒。此外,学习效果为 11 秒(5.03%)。

结论

Glittre-ADL 测试在评估哮喘成年人的 ADL 方面是有效且可靠的。然而,观察到明显的学习效果,因此最好采用两次测量中的最佳值,以避免低估。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验