压缩敏感编码的磁共振回波平面成像(EPICS):在头颈部弥散加权成像中的应用。

Echo planar imaging with compressed sensitivity encoding (EPICS): Usefulness for head and neck diffusion-weighted MRI.

机构信息

Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Japan.

Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Japan.

出版信息

Eur J Radiol. 2022 Oct;155:110489. doi: 10.1016/j.ejrad.2022.110489. Epub 2022 Aug 17.

Abstract

PURPOSE

To evaluate diffusion-weighted imaging (DWI) using echo planar imaging (EPI) with compressed SENSE (EPICS) of the head and neck magnetic resonance imaging (MRI).

METHOD

We retrospectively observed 32 patients who underwent head and neck DWI according to either the conventional method (SENSE, reduction factor = 2), fast scanning method (SENSE, reduction factor = 4), or fast scanning method with EPICS (EPICS, reduction factor = 4). For quantitative analysis, contrast-to-noise-ratio (CNR), apparent diffusion coefficient (ADC) values, geometric distortion, and coefficient of variations (CV) were measured and compared. For qualitative analysis, all images were independently and blindly evaluated by two board-certified radiologists.

RESULTS

EPICS revealed the higher CNR between all location compared to those of SENSE with reduction factor = 4. Distortion in the anterior-posterior direction was significantly lower on EPICS than on the conventional scan (p = 0.02). A comparison between the ADC values of the EPICS and conventional scan revealed no significant differences. The CV was significantly lower for EPICS than the conventional scan [DWI: 0.22 (IQR: 0.15-0.30) vs 0.32 (IQR: 0.24-0.40), p = 0.02].

CONCLUSIONS

Compressed SENSE combined with the high acceleration factor can improve image quality, homogeneity, and distortion in the head and neck DWI maintaining ADC values and the scan time duration.

摘要

目的

评估头部和颈部磁共振成像(MRI)中使用压缩感应(EPICS)的 echo 平面成像(EPI)进行弥散加权成像(DWI)。

方法

我们回顾性观察了 32 名接受头部和颈部 DWI 的患者,他们分别采用常规方法(SENSE,缩减因子=2)、快速扫描方法(SENSE,缩减因子=4)或快速扫描方法加 EPICS(EPICS,缩减因子=4)进行扫描。进行定量分析时,测量并比较了对比噪声比(CNR)、表观扩散系数(ADC)值、几何变形和变异系数(CV)。进行定性分析时,由两名持有证书的放射科医生独立、盲法评估所有图像。

结果

与 SENSE 缩减因子=4 相比,EPICS 在所有部位均显示出更高的 CNR。EPICS 在前-后方向上的失真明显低于常规扫描(p=0.02)。EPICS 与常规扫描的 ADC 值比较无显著差异。EPICS 的 CV 明显低于常规扫描[DWI:0.22(IQR:0.15-0.30)比 0.32(IQR:0.24-0.40),p=0.02]。

结论

压缩感应与高加速因子相结合可以改善头部和颈部 DWI 的图像质量、均匀性和失真,同时保持 ADC 值和扫描时间。