Int Orthop. 2022 Nov;46(11):2539-2546. doi: 10.1007/s00264-022-05556-1. Epub 2022 Aug 30.
The use of dual mobility cups (DMC) has been shown to reduce hip instability after revision surgery. For severe acetabular bone loss, reconstruction with a Kerboull cross-plate and bone allograft would contribute to restoring native hip position and bone stock. Only two papers reported on the combination of Kerboull cross-plate with bone allograft and cemented DMC in revision total hip arthroplasty (THA).
This is a monocentric retrospective study (28 cases) of first-time revision THA using such a construct in American Association of Orthopaedic Surgeons (AAOS) grade III and IV acetabular bone defect. Detailed demographic, clinical and radiographic results were recorded and evaluated.
With a mean follow-up of six ± 3.63 years, no case of instability was reported. The modified Harris Hip Score (mHHS) was 88.4 ± 10.1. No hook fracture or mechanical failure was observed. Non-progressive radiolucent lines were recorded. Osteointegration of the allografts was observed in all cases with a mean Grodet score of 7.9 ± 0.97.
In first revision THA, the use of a Kerboull cross-plate with allograft and a cemented DMC in AAOS grade III and IV acetabular bone defects demonstrated excellent clinical and radiological outcomes with no recorded cases of dislocation or mechanical failure.
双动杯(DMC)的使用已被证明可减少翻修手术后的髋关节不稳定。对于严重的髋臼骨缺损,使用 Kerboull 交叉板和骨移植物重建有助于恢复髋关节的正常位置和骨量。仅有两篇文献报道了 Kerboull 交叉板与骨移植物和骨水泥固定的 DMC 在翻修全髋关节置换术中的联合应用。
这是一项单中心回顾性研究(28 例),研究对象为美国矫形外科医师协会(AAOS)髋臼骨缺损 III 级和 IV 级的初次翻修全髋关节置换术患者,使用这种结构。详细记录和评估了人口统计学、临床和影像学结果。
平均随访 6±3.63 年,无不稳定病例报告。改良 Harris 髋关节评分(mHHS)为 88.4±10.1。未观察到钩状骨折或机械故障。记录到非进行性透亮线。所有病例均观察到同种异体移植物的骨整合,Grodet 评分平均为 7.9±0.97。
在初次翻修全髋关节置换术中,在 AAOS 髋臼骨缺损 III 级和 IV 级中使用 Kerboull 交叉板与同种异体骨和骨水泥固定的 DMC,临床和影像学结果均非常出色,无脱位或机械故障病例。