Suppr超能文献

通过使用患者特异性 3D 打印切割引导器,对儿科肾肿瘤进行 MRI 与组织病理学的直接相关性研究:一项可行性研究。

Direct correlation of MRI with histopathology in pediatric renal tumors through the use of a patient-specific 3-D-printed cutting guide: a feasibility study.

机构信息

Princess Máxima Center for Pediatric Oncology, Utrecht, The Netherlands.

Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.

出版信息

Pediatr Radiol. 2023 Feb;53(2):235-243. doi: 10.1007/s00247-022-05476-7. Epub 2022 Aug 30.

Abstract

BACKGROUND

Pediatric renal tumors are often heterogeneous lesions with variable regions of distinct histopathology. Direct comparison between in vivo imaging and ex vivo histopathology might be useful for identification of discriminating imaging features.

OBJECTIVE

This feasibility study explored the use of a patient-specific three-dimensional (3D)-printed cutting guide to ensure correct alignment (orientation and slice thickness) between magnetic resonance imaging (MRI) and histopathology.

MATERIALS AND METHODS

Before total nephrectomy, a patient-specific cutting guide based on each patient's preoperative renal MRI was generated and 3-D printed, to enable consistent transverse orientation of the histological specimen slices with MRI slices. This was expected to result in macroscopic slices of 5 mm each. The feasibility of the technique was determined qualitatively, through questionnaires administered to involved experts, and quantitatively, based on structured measurements including overlap calculation using the dice similarity coefficient.

RESULTS

The cutting guide was used in eight Wilms tumor patients receiving a total nephrectomy, after preoperative chemotherapy. The median age at diagnosis was 50 months (range: 4-100 months). The positioning and slicing of the specimens were rated overall as easy and the median macroscopic slice thickness of each specimen ranged from 5 to 6 mm. Tumor consistency strongly influenced the practical application of the cutting guide. Digital correlation of a total of 32 slices resulted in a median dice similarity coefficient of 0.912 (range: 0.530-0.960).

CONCLUSION

We report the feasibility of a patient-specific 3-D-printed MRI-based cutting guide for pediatric renal tumors, allowing improvement of the correlation of MRI and histopathology in future studies.

摘要

背景

小儿肾肿瘤常为异质性病变,具有不同区域的明显组织病理学特征。活体成像与离体组织病理学之间的直接比较可能有助于识别有区别的成像特征。

目的

本研究旨在探索使用患者特异性的三维(3D)打印切割引导器来确保磁共振成像(MRI)与组织病理学之间的正确对准(方向和切片厚度)。

材料与方法

在全肾切除术前,基于每位患者的术前肾脏 MRI 生成并 3D 打印患者特异性的切割引导器,以实现组织学标本切片与 MRI 切片的横向一致取向。预计这将导致每个宏观切片厚度为 5mm。通过向相关专家发放调查问卷,以及通过使用骰子相似系数进行重叠计算等结构测量进行定量评估,来确定该技术的可行性。

结果

该切割引导器在 8 例接受术前化疗的 Wilms 肿瘤患者中用于全肾切除术。诊断时的中位年龄为 50 个月(范围:4-100 个月)。标本的定位和切片总体上被评为容易,每个标本的中位宏观切片厚度范围为 5-6mm。肿瘤的一致性强烈影响了切割引导器的实际应用。总共 32 个切片的数字相关性得出的骰子相似系数中位数为 0.912(范围:0.530-0.960)。

结论

我们报告了一种基于患者特异性 3D 打印 MRI 的用于小儿肾肿瘤的切割引导器的可行性,这可能有助于未来研究中改善 MRI 与组织病理学之间的相关性。