The study evaluated leukocyte esterase (LE) and nitrite reagent pad usefulness in canine urine using multiple time endpoints and decision thresholds. Whole and sedimented urine samples from 116 client-owned dogs were analyzed with reagent strips from four manufacturers. Results for LE and nitrite were recorded every 30 s up to 150 s using "trace" and "+" positive thresholds and compared to microscopic urine sediment analysis and culture results. Sedimented urine assessed at 150 s with a "trace" positive threshold for LE had significantly or trending higher sensitivity (brand dependent) for pyuria detection compared with manufacturer recommendations. Using these parameters, LE sensitivity and negative likelihood ratio were 66.67-89.47%, and 0.13-0.37, respectively. Following manufacturer recommendations, LE specificity and positive likelihood ratio were 96.91-100% and 17.02-30.63, respectively. Nitrite performance for pyuria and bacteriuria detection was poor for all conditions. LE reagent pads are a useful screening test for pyuria detection using sedimented urine and a "trace" positive threshold at 150 s, whereas LE use with traditional manufacturer recommendations is a good confirmatory test for pyuria detection. Nitrite reagent pads are not useful for pyuria or bacteriuria detection.
本研究使用多个时间终点和决策阈值评估了白细胞酯酶(LE)和亚硝酸盐试剂条在犬尿液中的应用。对 116 只宠物犬的全尿和沉渣尿样本进行了来自四个制造商的试剂条分析。使用“痕量”和“+”阳性阈值,记录了 LE 和亚硝酸盐的结果,每 30 秒记录一次,最长可达 150 秒,并与显微镜尿液沉渣分析和培养结果进行了比较。在 150 秒时使用“痕量”阳性阈值评估沉渣尿液中的 LE,与制造商的建议相比,对脓尿检测具有显著或趋势更高的敏感性(取决于品牌)。使用这些参数,LE 的敏感性和阴性似然比分别为 66.67-89.47%和 0.13-0.37。根据制造商的建议,LE 的特异性和阳性似然比分别为 96.91-100%和 17.02-30.63。对于脓尿和菌尿检测,亚硝酸盐的性能在所有条件下均较差。LE 试剂条是一种有用的筛选试验,可用于检测沉渣尿液中的脓尿,并在 150 秒时使用“痕量”阳性阈值,而 LE 结合传统制造商的建议,是脓尿检测的良好确认试验。亚硝酸盐试剂条不适用于脓尿或菌尿检测。