Measurement of corneal biomechanical properties in diabetes mellitus using the Corvis ST.

机构信息

Department of Ophthalmology, Yeouido St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.

出版信息

Medicine (Baltimore). 2022 Sep 9;101(36):e30248. doi: 10.1097/MD.0000000000030248.

Abstract

We sought to assess changes in corneal biomechanical parameters in patients with diabetes mellitus (DM) in comparison with those among healthy controls using Corvis ST (CST). The study group included 209 eyes from healthy control subjects and 33 eyes from diabetic subjects, respectively. Following an ophthalmological examination, measurements with CST were taken. Additionally, hemoglobin A1c and blood glucose values were collected. Results were then compared to those of the control group after adjusting for potential confounding factors, including age-, intraocular pressure (IOP)-, central corneal thickness (CCT)-, spherical equivalent (SE)- and axial length (AL). After adjusting for potential confounding factors, including the age, IOP, CCT, SE, and AL, patients with DM presented significantly lower whole-eye movement (WEM) (ms) values than patients without DM (21.71 ± 0.84 vs. 22.15 ± 0.64 ms; P < .001). There was a significant and negative correlation between WEM (ms) and hemoglobin A1c in DM patients (r = -0.733; P = .001). In univariate and multivariate general linear mixed model (GLMM) analyses, IOP (P < .001 and P < .001, respectively) and the presence of DM (P = .001 and P < .001, respectively) significantly affected WEM (ms). In DM, significant changes in corneal biomechanical properties were detectable. The DM group showed significantly less deformable cornea and sclera than did the normal controls, even after adjusting for age, IOP, CCT, SE, and AL. These findings may cause misinterpretation of IOP measurements in diabetic patients. Therefore, the measurement of corneal biomechanics should be taken into consideration in clinical practice.

摘要

我们旨在使用 Corvis ST(CST)评估糖尿病(DM)患者的角膜生物力学参数变化,并与健康对照组进行比较。研究组包括 209 只来自健康对照组的眼睛和 33 只来自糖尿病组的眼睛。在眼科检查后,使用 CST 进行测量。此外,还收集了血红蛋白 A1c 和血糖值。然后,在调整了年龄、眼内压(IOP)、中央角膜厚度(CCT)、等效球镜(SE)和眼轴(AL)等潜在混杂因素后,将结果与对照组进行比较。在调整了年龄、IOP、CCT、SE 和 AL 等潜在混杂因素后,DM 患者的整体眼球运动(WEM)(ms)值明显低于非 DM 患者(21.71±0.84 vs. 22.15±0.64 ms;P<0.001)。DM 患者的 WEM(ms)与血红蛋白 A1c 呈显著负相关(r=-0.733;P=0.001)。在单变量和多变量一般线性混合模型(GLMM)分析中,IOP(P<0.001 和 P<0.001,分别)和 DM 的存在(P=0.001 和 P<0.001,分别)显著影响 WEM(ms)。在 DM 中,即使在调整年龄、IOP、CCT、SE 和 AL 后,也可以检测到角膜生物力学特性的显著变化。DM 组的角膜和巩膜变形性明显低于正常对照组。这些发现可能导致对糖尿病患者的 IOP 测量的错误解释。因此,在临床实践中应考虑角膜生物力学的测量。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f7e8/10980441/8b87b9c4a1e6/medi-101-e30248-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验