Child Obes. 2023 Oct;19(7):470-478. doi: 10.1089/chi.2022.0084. Epub 2022 Oct 5.
It is essential to quantify the accuracy and precision of bioelectrical impedance (BIA)-estimated percent body fat (%BF) to better interpret community-based research findings that utilize opportunistic measures. Study 1 measured the accuracy of a new dual-frequency foot-to-foot BIA device (Tanita DC-430U) compared with dual-energy X-ray absorptiometry (DXA) among healthy elementary school-aged children ( = 50). Study 2 examined the precision of BIA %BF estimates within and between days among children and adults ( = 38). Regarding accuracy, Tanita DC-430U underestimated %BF by 8.0 percentage points compared with DXA (20.6% vs. 28.5%), but correctly ranked children in terms of %BF. Differences in %BF between BIA and DXA were driven by lower BIA-estimated fat mass (7.8 kg vs. 9.9 kg, < 0.05) and higher BIA-estimated fat-free mass (25.3 kg vs. 24.1 kg, < 0.05). The absolute agreement between BIA and DXA for estimated %BF was moderate (concordance correlation coefficients = 0.53). Regarding precision, measures taken at the same time, but on different days (root mean square standard deviation [RMSD] = 0.42-0.74) were more precise than the measures taken at different times within a single day (RMSD = 1.04-1.10). The Tanita DC-430U substantially underestimated %BF compared with DXA, highlighting the need to assess accuracy of new BIA devices when they are introduced to the market. Opportunistic measures of %BF estimates were most precise when taken at consistent times and in the morning, but may be utilized throughout the day with an understanding of within- and between-day variability.
定量评估生物电阻抗(BIA)估计的体脂肪百分比(%BF)的准确性和精密度对于更好地解释基于社区的研究结果至关重要,这些研究结果利用了机会性测量方法。研究 1 测量了一种新的双频足底-足底 BIA 设备(Tanita DC-430U)与健康小学生(n=50)之间双能 X 射线吸收法(DXA)相比的准确性。研究 2 检查了儿童和成人 BIA %BF 估计值在日内和日间的精密度(n=38)。在准确性方面,与 DXA 相比,Tanita DC-430U 低估了 8.0 个百分点的 %BF(20.6%对 28.5%),但正确地按 %BF 对儿童进行了排名。BIA 和 DXA 之间 %BF 的差异是由 BIA 估计的脂肪量较低(7.8kg 对 9.9kg,<0.05)和 BIA 估计的去脂体重较高(25.3kg 对 24.1kg,<0.05)所致。BIA 和 DXA 之间估计的 %BF 的绝对一致性是中等的(一致性相关系数=0.53)。在精密度方面,在同一时间但在不同天进行的测量(均方根标准偏差 [RMSD] = 0.42-0.74)比在一天内不同时间进行的测量更精确(RMSD = 1.04-1.10)。与 DXA 相比,Tanita DC-430U 大大低估了 %BF,这突出表明在新的 BIA 设备推向市场时,需要评估其准确性。在一致的时间和早上进行 %BF 估计的机会性测量最精确,但如果了解日内和日间的可变性,也可以在一天中的任何时间使用。