Suppr超能文献

一种测定管状膜电容的新方法:细胞外液电导率降低时的被动膜电特性。

A new approach to the determination of tubular membrane capacitance: passive membrane electrical properties under reduced electrical conductivity of the extracellular solution.

机构信息

Department of Physiology, Faculty of Medicine, Masaryk University, Kamenice 5, 625 00, Brno, Czech Republic.

Department of Internal Medicine and Cardiology, University Hospital Brno and Faculty of Medicine, Masaryk University, Jihlavská 20, 625 00, Brno, Czech Republic.

出版信息

Pflugers Arch. 2022 Dec;474(12):1263-1274. doi: 10.1007/s00424-022-02756-x. Epub 2022 Oct 14.

Abstract

The transverse-axial tubular system (tubular system) of cardiomyocytes plays a key role in excitation-contraction coupling. To determine the area of the tubular membrane in relation to the area of the surface membrane, indirect measurements through the determination of membrane capacitances are currently used in addition to microscopic methods. Unlike existing electrophysiological methods based on an irreversible procedure (osmotic shock), the proposed new approach uses a reversible short-term intermittent increase in the electrical resistance of the extracellular medium. The resulting increase in the lumen resistance of the tubular system makes it possible to determine separate capacitances of the tubular and surface membranes. Based on the analysis of the time course of the capacitive current, computational relations were derived to quantify the elements of the electrical equivalent circuit of the measured cardiomyocyte including both capacitances. The exposition to isotonic low-conductivity sucrose solution is reversible which is the main advantage of the proposed approach allowing repetitive measurements on the same cell under control and sucrose solutions. Experiments on rat ventricular cardiomyocytes (n = 20) resulted in the surface and tubular capacitance values implying the fraction of tubular capacitance/area of 0.327 ± 0.018. We conclude that the newly proposed method provides results comparable to the data obtained by the currently used detubulation method and, in addition, by being reversible, allows repeated evaluation of surface and tubular membrane parameters on the same cell.

摘要

心肌细胞的横轴向管状系统(管状系统)在兴奋-收缩偶联中起着关键作用。为了确定管状膜面积与表面膜面积的关系,除了微观方法外,目前还使用通过确定膜电容的间接测量。与基于不可逆过程(渗透压冲击)的现有电生理学方法不同,所提出的新方法使用可逆的短期间歇性增加细胞外介质的电阻。管状系统的管腔电阻的增加使得可以确定管状和表面膜的单独电容。基于对电容电流时程的分析,推导出了计算关系,以量化测量的心肌细胞的电路等效元件,包括两个电容。暴露于等渗低导率蔗糖溶液是可逆的,这是所提出方法的主要优势,允许在对照和蔗糖溶液下对同一细胞进行重复测量。在大鼠心室心肌细胞(n = 20)上进行的实验得出了表面和管状电容值,这意味着管状电容/面积的分数为 0.327 ± 0.018。我们得出的结论是,新提出的方法提供的结果可与当前使用的去管方法获得的数据相媲美,此外,由于具有可逆性,还允许在同一细胞上重复评估表面和管状膜参数。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5a8d/9663357/e05e5833d382/424_2022_2756_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验