Suppr超能文献

护理工作中断量表的编制与验证。

Development and Validation of a Nursing Work Interruption Scale.

机构信息

Nursing Department, Busan Institute of Science and Technology, Busan 6639, Korea.

College of Nursing, Dong-A University, Busan 49201, Korea.

出版信息

Int J Environ Res Public Health. 2022 Oct 18;19(20):13487. doi: 10.3390/ijerph192013487.

Abstract

Work interruption disturbs nurses' flow of thinking, diminishes work efficiency, induces burnout, and causes errors that can threaten patients' lives. Therefore, it is important to identify the causes and measure the extent of work interruption. This study developed a self-report scale and established its validity and reliability for use in hospital settings. Through literature review and in-depth interviews with nurses, we identified two components and developed 25 preliminary items. These items were reviewed by nursing experts for content validity and pilot tested among 20 hospital nurses; subsequently, a 16-item preliminary instrument was finalized. A total of 359 questionnaires were included in the final analysis, and exploratory factor analysis (EFA) and confirmatory factor analysis (CFA) were performed. Two factors and 12 items were derived from two rounds of EFA, with a cumulative percentage of variance of 55.73%. Construct validity was established through CFA. The predictive validity and internal consistency reliability of the developed scale were also established. Thus, the 12-item Work Interruption Measurement Scale for Nurses comprising two domains (human and environmental factors) was developed. This scale can be useful in assessing work interruption experienced by nurses and for developing and assessing the effectiveness of interventions pertaining to nurses' work interruption.

摘要

工作中断会打乱护士的思维流程,降低工作效率,导致倦怠,并引发可能威胁患者生命的错误。因此,识别工作中断的原因并衡量其程度非常重要。本研究开发了一种自我报告量表,并在医院环境中验证了其有效性和可靠性。通过文献回顾和对护士的深入访谈,我们确定了两个组成部分,并开发了 25 个初步项目。这些项目由护理专家进行内容有效性审查,并在 20 名医院护士中进行了试点测试;随后,确定了一个包含 16 个项目的初步工具。共有 359 份问卷纳入最终分析,进行了探索性因子分析(EFA)和验证性因子分析(CFA)。两轮 EFA 得出了两个因素和 12 个项目,累积方差百分比为 55.73%。通过 CFA 建立了结构有效性。还确定了开发量表的预测有效性和内部一致性可靠性。因此,开发了由两个领域(人为因素和环境因素)组成的 12 项护士工作中断测量量表。该量表可用于评估护士经历的工作中断,并用于评估和制定针对护士工作中断的干预措施的效果。

相似文献

1
Development and Validation of a Nursing Work Interruption Scale.护理工作中断量表的编制与验证。
Int J Environ Res Public Health. 2022 Oct 18;19(20):13487. doi: 10.3390/ijerph192013487.
5
Development and Validation of the Medication Safety Competence Scale for Nurses.护士用药安全能力量表的编制与验证
West J Nurs Res. 2021 Jul;43(7):686-697. doi: 10.1177/0193945920969929. Epub 2020 Nov 6.
6
[Development of a Reward Scale for Hospital Nurses].[医院护士奖励量表的编制]
J Korean Acad Nurs. 2023 Oct;53(5):525-537. doi: 10.4040/jkan.23057.

本文引用的文献

7
Development and validation of the Workplace Interruptions Measure.工作场所干扰测量工具的开发与验证。
Stress Health. 2018 Feb;34(1):102-114. doi: 10.1002/smi.2765. Epub 2017 Jun 22.
10
The Triage Interruptions Assessment Tool: An Instrument Development.分诊中断评估工具:一种工具的开发
Adv Emerg Nurs J. 2016 Oct/Dec;38(4):308-319. doi: 10.1097/TME.0000000000000121.