3D 打印(选择性激光烧结)、CAD/CAM 和失蜡技术钴铬冠边缘不匹配与肩台和倒角线:一项体外研究。

Marginal Misfit of 3D-Printed (Selective Laser Sintered), CAD-CAM and Lost Wax Technique Cobalt Chromium Copings with Shoulder and Chamfer Finish Lines: An In-Vitro Study.

机构信息

Department of Prosthetic Dental Science, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia.

Department of General Dentistry, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia.

出版信息

Medicina (Kaunas). 2022 Sep 20;58(10):1313. doi: 10.3390/medicina58101313.

Abstract

The aim was to compare the Misfit of 3D-Printed, Selective laser melting (SLM), milled (Computer aided design-Computer aided manufacture CAD-CAM) and Lost wax technique (LWT) fabricated Cobalt chromium (CoCr) alloy copings on shoulder (SH), radial shoulder (R-SH) and chamfer (CH) finish line configuration. Ninety resin, second maxillary premolar teeth were prepared for metal-ceramic crowns, equally divided into ( = 30) SH, R-SH and CH margin preparations. For each preparation design (SH, R-SH and CH), CoCr copings were prepared using SLM, CAD-CAM and LWT. This resulted in nine study groups with 10 CoCr copings each. The marginal misfit of specimens was assessed with a high-resolution digital microscope. Misfit was evaluated in vertical and horizontal dimensions in μm. Data were analyzed using ANOVA and a post hoc multiple comparisons test. For vertical misfit, the highest was observed in SLM samples with chamfer margin (167.96 ± 24.1), and the least was shown by CAD-CAM samples with radial shoulder (58.8 ± 12.53). CAD-CAM and shoulder margins showed the least vertical misfit. For horizontal misfit, the maximum was observed in SLM samples with shoulder margin (137.94 ± 37.85) and the least by LWT samples with chamfer (89.38 ± 14.81). Chamfer margins and LWT samples showed the least horizontal misfit among the group samples. Fabrication technique and finish line design play a critical role in reducing the marginal misfit of CoCr copings. For vertical misfit, SLM copings showed poor outcomes compared to CAD-CAM specimens, however comparable outcomes to Cast specimens. SLM copings showed comparable horizontal misfit outcomes to CAD-CAM specimens and low misfit compared to Cast copings, respectively. Vertical misfit was low with shoulder margins, and horizontal misfit was better with chamfer marginal configuration.

摘要

目的是比较 3D 打印、选择性激光熔化(SLM)、铣削(计算机辅助设计-计算机辅助制造 CAD-CAM)和失蜡技术(LWT)制造的钴铬(CoCr)合金修复体在肩台(SH)、斜肩台(R-SH)和倒角(CH)边缘线形态上的差异。90 颗树脂,第二上颌前磨牙准备用于金属陶瓷冠,分为(=30)SH、R-SH 和 CH 边缘准备。对于每个预备设计(SH、R-SH 和 CH),使用 SLM、CAD-CAM 和 LWT 制备 CoCr 修复体。这导致 9 个研究组,每组有 10 个 CoCr 修复体。使用高分辨率数字显微镜评估样本的边缘拟合误差。以μm为单位评估垂直和水平方向上的拟合误差。使用方差分析和事后多重比较检验对数据进行分析。对于垂直拟合误差,带有斜肩台边缘的 SLM 样本最大(167.96±24.1μm),带有斜肩台边缘的 CAD-CAM 样本最小(58.8±12.53μm)。CAD-CAM 和肩台边缘的垂直拟合误差最小。对于水平拟合误差,带有肩台边缘的 SLM 样本最大(137.94±37.85μm),带有倒角的 LWT 样本最小(89.38±14.81μm)。在组样本中,倒角边缘和 LWT 样本的水平拟合误差最小。制造技术和边缘线设计在降低 CoCr 修复体边缘拟合误差方面起着至关重要的作用。对于垂直拟合误差,与 CAD-CAM 样本相比,SLM 样本结果较差,但与铸造样本结果相当。与 CAD-CAM 样本相比,SLM 样本的水平拟合误差相当,与铸造样本相比,水平拟合误差较低。肩台边缘的垂直拟合误差较低,倒角边缘形态的水平拟合误差较好。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/21a3/9610473/fa2d08e7c235/medicina-58-01313-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验