Suppr超能文献

老年人心肌血运重建术前和术后的简短体能测试组合:可靠性、血流动力学反应、主观用力感觉及不良事件

Short physical performance battery in the pre and postoperative myocardial revascularization surgery in older adults: Reliability, hemodynamic responses, subjective perceived exertion, and adverse events.

作者信息

Ferronato Letícia, Vieira Danielle, Rodrigues Ana, Coronel Christian, de Avelar Núbia Pereira

机构信息

Laboratory of Aging, Resources and Rheumatology, Department of Health Sciences, Federal University of Santa Catarina, Campus Araranguá, Santa Catarina, Brazil.

Integrated Multiprofessional Residency in Health: Physiotherapy in Cardiology at IC/FUC, Porto Alegre, Brazil.

出版信息

Physiother Theory Pract. 2024 Jun;40(6):1110-1120. doi: 10.1080/09593985.2022.2137383. Epub 2022 Oct 28.

Abstract

INTRODUCTION

The Short Physical Performance Battery (SPPB) may be feasible for evaluating older adults undergoing myocardial revascularization surgery (MRS). However, it is necessary to verify its measurement properties and safety to use it for clinical practice.

OBJECTIVE

To investigate the reliability, hemodynamic responses, subjective perceived exertion (SPE), and adverse events during and after SPPB in older adults undergoing MRS.

MATERIALS AND METHODS

A cross-sectional and methodological study conducted with 85 older adults in the pre and postoperative periods of MRS. The hemodynamic responses [heart rate (HR) and systolic blood pressure (SBP)], SPE, and adverse events were evaluated before and after the SPPB. Two researchers performed the inter-rater reliability within a 30-minute interval, while the interval between measures for intra-rater reliability was 24 hours. The Friedman test was used to analyze hemodynamic and SPE responses. The intraclass correlation coefficient (ICC) and the coefficient variation of method error (CV) were used for the reliability analysis.

RESULTS

Increases in HR (p < 001), SBP (p < 0.01), and SPE (p < 0.01) were observed immediately after the SPPB. Only seven volunteers reported minor adverse events. Regarding reliability results, ICC for intra-rater reliability varied from 0.66 to 0.87 and CV from 4.80 to 8.82%. For inter-rater reliability, ICC varied from 0.66 to 0.91 and CV from 4.04 to 9.02%.

CONCLUSION

The SPPB increased the HR, SBP, and SPE immediately after its execution. In addition, it showed light changes in SPE, few adverse events, and good reliability in older adults in the pre and postoperative MRS period.

摘要

引言

简短体能测试电池(SPPB)可能适用于评估接受心肌血运重建手术(MRS)的老年人。然而,有必要验证其测量特性和用于临床实践的安全性。

目的

研究接受MRS的老年人在进行SPPB期间及之后的可靠性、血流动力学反应、主观用力感觉(SPE)和不良事件。

材料与方法

对85名老年人在MRS术前和术后进行了一项横断面和方法学研究。在SPPB前后评估血流动力学反应[心率(HR)和收缩压(SBP)]、SPE和不良事件。两名研究人员在30分钟间隔内进行评分者间可靠性评估,而评分者内可靠性测量的间隔为24小时。使用Friedman检验分析血流动力学和SPE反应。使用组内相关系数(ICC)和方法误差变异系数(CV)进行可靠性分析。

结果

SPPB后立即观察到HR(p < 0.001)、SBP(p < 0.01)和SPE(p < 0.01)升高。只有7名志愿者报告了轻微不良事件。关于可靠性结果,评分者内可靠性的ICC从0.66到0.87不等,CV从4.80%到8.82%不等。对于评分者间可靠性,ICC从0.66到0.91不等,CV从4.04%到9.02%不等。

结论

SPPB实施后立即增加了HR、SBP和SPE。此外,在MRS术前和术后的老年人中,它显示出SPE的轻微变化、不良事件较少且可靠性良好。