Suppr超能文献

三种数字咬合分析方法可靠性和有效性的体内评估。

In vivo evaluation of the reliability and validity of three digital occlusion analysis methods.

机构信息

State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, 710032, China.

The Graduate School, Augusta University, Augusta, GA 30912, United States.

出版信息

J Dent. 2022 Dec;127:104355. doi: 10.1016/j.jdent.2022.104355. Epub 2022 Nov 1.

Abstract

OBJECTIVES

The reliability and validity of three digital occlusion analysis methods was evaluated in vivo.

METHODS

The three method evalueated were:scanning of articulating paper marks (SA), dental prescale occlusal analysis system (DP) and a virtual occlusion constructed method (VO). A conventional silicone transmission method (ST) was used as the standard for comparison. Each of the 20 enroled human subjects was tested with the four methods. Retest of each method was performed at 2-week intervals. Occlusal contact area (OCA) and occlusal contact numbers (OCN) were calculated for analyses. For reliability evaluation, intraclass correlation coefficients (ICC) of the OCA and OCN values obtained from each method were compared. For validity evaluation, Pearson correlations coefficients, paired t-tests, regression analysis and Bland-Altman analysis were examined.

RESULTS

The ICC values of OCA and OCN were in the order: ST>SA>DP>VO. The highest OCA and OCN values were found ST while the lowest values were obtained from DP. Paired t-test identified a significant difference when OCA values obtained from the three digital methods were compared with ST, and between the OCN values of DP and ST. Pearson correlation showed high coefficients between ST and three digital methods (0.583-0.885 for OCA; 0.779-0.836 for OCN). A significant linear correlation was found between the results from ST and those from SA or VO. Bland-Altman analysis showed good agreement between OCN values of SA and ST, and between those of VO and ST.

CONCLUSIONS

The three digital occlusal analysis methods showed good reliability and validity for in vivo clinical application.

CLINICAL SIGNIFICANCE

The three digital occlusion analysis systems examined demonstrate good potential in in vivo quantitative analysis, with good reliability and validity. The use of these analytical methods should facilitate digital workflow in clinical practice.

摘要

目的

评估三种数字化咬合分析方法的可靠性和有效性。

方法

评估的三种方法为:咬合记录纸描记扫描(SA)、牙尖比例咬合分析系统(DP)和虚拟咬合构建方法(VO)。常规硅橡胶转移法(ST)被用作比较的标准。20 名入组的受试者分别用这四种方法进行测试。每种方法在 2 周的间隔内进行复测。计算了咬合接触面积(OCA)和咬合接触数量(OCN)进行分析。为了评估可靠性,比较了每种方法获得的 OCA 和 OCN 值的组内相关系数(ICC)。为了评估有效性,进行了 Pearson 相关系数、配对 t 检验、回归分析和 Bland-Altman 分析。

结果

OCA 和 OCN 的 ICC 值顺序为:ST>SA>DP>VO。ST 获得的 OCA 和 OCN 值最高,而 DP 获得的最低。配对 t 检验发现,当将三种数字化方法获得的 OCA 值与 ST 进行比较时,以及 DP 和 ST 的 OCN 值之间存在显著差异。Pearson 相关显示 ST 与三种数字化方法之间具有高度相关系数(OCA 为 0.583-0.885;OCN 为 0.779-0.836)。在 ST 和 SA 或 VO 的结果之间发现了显著的线性相关性。Bland-Altman 分析显示 SA 和 ST 的 OCN 值之间以及 VO 和 ST 的 OCN 值之间具有良好的一致性。

结论

三种数字化咬合分析方法在临床应用中具有良好的可靠性和有效性。

临床意义

检查的三种数字化咬合分析系统在体内定量分析中具有良好的潜力,具有良好的可靠性和有效性。这些分析方法的使用将有助于临床实践中的数字化工作流程。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验