Khan Nadeem A, Morabet Rachida El, Khan Roohul Abad, Alsubih Majed, Gaurav Gajendra Kumar, Klemeš Jiří Jaromír, Thakur Amit K
Department of Civil Engineering, Mewat Engineering College, 122107 Nuh, Haryana, India.
Department of Geography, LADES, FLSH-M, Hassan II University of Casablanca, 47963 Mohammedia, Morocco.
Biomass Convers Biorefin. 2022 Nov 1:1-16. doi: 10.1007/s13399-022-03406-z.
Hospital wastewater treatment is gaining attention in recent studies due to its complex nature. The performance of the sequencing batch reactor coupled with tube-settler was investigated for hospital wastewater treatment. The performance was evaluated regarding removing organic matter and nutrients (nitrate and phosphate). The phosphate was removed in the sequencing batch reactor and its associated tube-settler with a 60% removal efficiency margin. Nitrification was observed in sequencing batch reactor and tube-settler, but denitrification could not be achieved. The nitrification-denitrification process was not completed during the process. The current work's main aim was to understand and optimise the operational parameters involved in the performance of the sequencing batch reactor. The operational parameters were optimised using Design expert software, and Response Surface Methodology involved a four-factor and five-level central composite design. The percentage removal of chemical oxygen demand, nitrate, and phosphate was selected to be observed during this study.
The online version contains supplementary material available at 10.1007/s13399-022-03406-z.
由于医院废水性质复杂,近年来其处理问题受到越来越多的关注。研究了序批式反应器与斜管沉淀器联用处理医院废水的性能。从去除有机物和营养物质(硝酸盐和磷酸盐)方面对其性能进行了评估。在序批式反应器及其相关的斜管沉淀器中,磷酸盐的去除效率达到了60%。在序批式反应器和斜管沉淀器中观察到了硝化作用,但反硝化作用未能实现。在此过程中硝化-反硝化过程未完成。当前工作的主要目的是了解并优化序批式反应器性能所涉及的运行参数。使用Design expert软件对运行参数进行了优化,响应面法采用了四因素五水平的中心复合设计。本研究期间选取了化学需氧量、硝酸盐和磷酸盐的去除率进行观测。
在线版本包含可在10.1007/s13399-022-03406-z获取的补充材料。