Suppr超能文献

建议的埃塞俄比亚亚的斯亚贝巴儿科 X 射线优化可能的局部诊断参考水平。

Suggested Local Diagnostic Reference Levels for Possible Pediatric X-Ray Optimization in Addis Ababa, Ethiopia.

机构信息

Department of Radiology, College of Health Sciences, Addis Ababa University.

出版信息

Ethiop J Health Sci. 2022 Oct;32(Spec Iss 1):11-16. doi: 10.4314/ejhs.v32i1.3S.

Abstract

BACKGROUND

Early childhood radiation exposure carries an enhanced radiation risk of about two to three times as high as in adults. The objective of this study was to determine local diagnostic reference levels for the most frequent pediatric x-ray examinations in Addis Ababa, Ethiopia.

METHODS

A cross-sectional study was conducted on 18 public and private hospitals/clinics in Addis Ababa. A total of 864 pediatric patients, undergoing eight types of routine x-ray examinations with 13 projections were evaluated from December 18/2017 to March 17 /2018. All pediatrics were categorized under four age groups. Anthropometric and radiographic parameters of each patient were recorded .The minimum, maximum, mean and third quartile values of entrance surface dose were analyzed using SPSS version 23. Finally, the suggested local diagnostic reference levels were compared with national and international reference dose values.

RESULTS

Of the 864 pediatric patients, chest (AP/PA), lower and upper extremity (AP/PA) accounted for 501(58%), 110 (13%) and 103 (12%) respectively, accounting to 714(83%) of the total pediatric x-ray examinations. The suggested local diagnostic reference levels of chest X-ray (AP/PA) examinations in mGy were: (0.09,0.13,0.17,0.17) for age group (0-<1,1-<5 ,5-<10, and 10-<15), respectively. Similarly, for same age group (0-<1,1-<5 ,5-<10, and 10-<15) the suggested local diagnostic reference levels of lower and upper extremities in mGy were: (0.06,0.08,0.09,0.09) and (0.04,0.05,0.05,0.06), respectively.

CONCLUSION

The suggested local diagnostic reference levels were slightly higher than the national and international guidance levels, indicating the need for establishment of diagnostic reference levels in the country.

摘要

背景

儿童早期辐射暴露的辐射风险比成人高 2 到 3 倍左右。本研究的目的是确定埃塞俄比亚亚的斯亚贝巴最常见的儿科 X 射线检查的局部诊断参考水平。

方法

这是一项在亚的斯亚贝巴的 18 家公立和私立医院/诊所进行的横断面研究。从 2017 年 12 月 18 日至 2018 年 3 月 17 日,对 864 名接受 8 种常规 X 射线检查和 13 个投影的儿科患者进行了评估。所有儿科患者分为四个年龄组。记录每位患者的人体测量和放射学参数。使用 SPSS 版本 23 分析入口表面剂量的最小值、最大值、平均值和第三四分位数值。最后,将建议的局部诊断参考水平与国家和国际参考剂量值进行比较。

结果

在 864 名儿科患者中,胸部(AP/PA)、下肢和上肢(AP/PA)分别占 501 例(58%)、110 例(13%)和 103 例(12%),占总儿科 X 射线检查的 714 例(83%)。胸部 X 射线(AP/PA)检查的建议局部诊断参考水平为 mGy:(0.09、0.13、0.17、0.17),分别为年龄组(0-<1、1-<5、5-<10 和 10-<15)。同样,对于相同的年龄组(0-<1、1-<5、5-<10 和 10-<15),建议的下肢和上肢局部诊断参考水平 mGy 分别为:(0.06、0.08、0.09、0.09)和(0.04、0.05、0.05、0.06)。

结论

建议的局部诊断参考水平略高于国家和国际指导水平,表明该国需要建立诊断参考水平。

相似文献

1
Suggested Local Diagnostic Reference Levels for Possible Pediatric X-Ray Optimization in Addis Ababa, Ethiopia.
Ethiop J Health Sci. 2022 Oct;32(Spec Iss 1):11-16. doi: 10.4314/ejhs.v32i1.3S.
7
Local Diagnostic Reference Levels for Common Adult Computed Tomography Procedures in Addis Ababa.
Dose Response. 2023 Apr 19;21(2):15593258231171492. doi: 10.1177/15593258231171492. eCollection 2023 Apr-Jun.
8
Assessment of radiation exposure among pediatric patients referred for CT imaging at three government hospitals in Addis Ababa, Ethiopia.
SAGE Open Med. 2024 Jul 27;12:20503121241266323. doi: 10.1177/20503121241266323. eCollection 2024.
9
Suggested diagnostic reference levels for paediatric X-ray examinations in India.
Radiat Prot Dosimetry. 2011 Nov;147(3):423-8. doi: 10.1093/rpd/ncq458. Epub 2010 Dec 8.
10
PROPOSED NATIONAL DIAGNOSTIC REFERENCE LEVELS FOR STANDARD RADIOGRAPHIC X-RAY PROCEDURES IN SUDAN.
Radiat Prot Dosimetry. 2020 Oct 16;190(4):419-426. doi: 10.1093/rpd/ncaa114.

本文引用的文献

1
DOSIMETRY OF ADULT AND PEDIATRIC PATIENTS FOR COMMON DIGITAL RADIOGRAPHY EXAMINATIONS.
Radiat Prot Dosimetry. 2018 Jun 1;179(4):349-357. doi: 10.1093/rpd/ncx293.
2
ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging.
Ann ICRP. 2017 Oct;46(1):1-144. doi: 10.1177/0146645317717209.
3
ESTABLISHMENT OF RADIATION DOSES FOR PEDIATRIC X-RAY EXAMINATIONS IN A LARGE PEDIATRIC HOSPITAL IN TURKEY.
Radiat Prot Dosimetry. 2017 Nov 1;176(3):302-308. doi: 10.1093/rpd/ncx010.
5
Establishment of local diagnostic reference levels in paediatric screen-film radiography at a children's hospital.
Radiat Prot Dosimetry. 2013 May;154(4):465-76. doi: 10.1093/rpd/ncs270. Epub 2012 Oct 22.
6
Local diagnostic reference levels for typical radiographic procedures.
Can Assoc Radiol J. 2012 Nov;63(4):237-41. doi: 10.1016/j.carj.2011.02.004. Epub 2011 Dec 2.
7
Diagnostic reference levels in pediatric radiology in Austria.
Eur Radiol. 2010 Jul;20(7):1572-9. doi: 10.1007/s00330-009-1697-7. Epub 2010 Jan 22.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验