Suppr超能文献

A 扫描参数与哈萨克人群中闭角型青光眼风险的关系。

A-Scan Parameters and the Risk of Phacomorphic Glaucoma in the Kazakh Population.

机构信息

Department of Ophthalmology, S.D. Asfendiyarov Kazakh National Medical University, Tolebe 94, Almaty 050000, Kazakhstan.

Department of Ophthalmology, The Central City Clinical Hospital, Zhandosov 6, Almaty 050000, Kazakhstan.

出版信息

Medicina (Kaunas). 2022 Oct 28;58(11):1544. doi: 10.3390/medicina58111544.

Abstract

Background and Objectives: The aim of our study was to identify risk factors associated with phacomorphic glaucoma (PG) by comparing the biometric parameters of contralateral eyes of patients with PG with the eyes of patients with a mature cataract. Methods: This retrospective case−control study included 71 eyes affected with PG, 311 eyes of control participants, and 71 contralateral eyes of patients with PG. All participants were ethnically Kazakh. Axial lengths (AL), anterior chamber depths (ACD), and lens thicknesses (LT) were measured using A-scan ultrasound biometry. To determine the threshold value of the A-scan parameters associated with PG, we performed ROC analysis. Results: The eyes with PG had smaller AL and ACD values and larger LT values, followed by the fellow eyes with PG and the control eyes. There were no differences in age and sex between patients with PG and mature cataracts. After adjustment for age and other A-scan parameters, continuous measures of ACD and LT were associated with PG (OR 0.57, 95% CI 0.38−0.73, p < 0.001; OR 3.36, 95% CI 1.64−6.912, p = 0.001). When A-scan parameters were dichotomized according to the identified threshold, an ACD of less than 2.5 mm (OR 3.113, 95% CI 1.562−6.204, p = 0.001) and an LT thicker than 4.75 mm (OR 26.368, 95% CI 9.130−76.158, p < 0.001) were found to be related to PG. Conclusions: We found that a thicker lens and, possibly, a shallow ACD are risk factors for PG.

摘要

背景和目的

本研究旨在通过比较青光眼合并白内障(PG)患者对侧眼与成熟白内障患者眼的生物测量参数,确定与 PG 相关的危险因素。方法:本回顾性病例对照研究纳入了 71 只患 PG 的眼、311 只对照眼和 71 只 PG 患者的对侧眼。所有参与者均为哈萨克族。使用 A 型超声生物测量仪测量眼轴长度(AL)、前房深度(ACD)和晶状体厚度(LT)。为了确定与 PG 相关的 A 扫描参数的阈值值,我们进行了 ROC 分析。结果:PG 眼中的 AL 和 ACD 值较小,LT 值较大,其次是 PG 患者的对侧眼和对照眼。PG 患者与成熟白内障患者的年龄和性别无差异。在调整年龄和其他 A 扫描参数后,ACD 和 LT 的连续测量值与 PG 相关(OR 0.57,95%CI 0.38-0.73,p<0.001;OR 3.36,95%CI 1.64-6.912,p=0.001)。当根据确定的阈值将 A 扫描参数分为二分类时,ACD 小于 2.5mm(OR 3.113,95%CI 1.562-6.204,p=0.001)和 LT 大于 4.75mm(OR 26.368,95%CI 9.130-76.158,p<0.001)与 PG 相关。结论:我们发现晶状体较厚和可能的 ACD 较浅是 PG 的危险因素。

相似文献

本文引用的文献

1
Glaucoma.青光眼。
Med Clin North Am. 2021 May;105(3):493-510. doi: 10.1016/j.mcna.2021.01.004. Epub 2021 Apr 2.
3
Acute angle closure glaucoma.急性闭角型青光眼
Br J Hosp Med (Lond). 2019 Dec 2;80(12):C174-C179. doi: 10.12968/hmed.2019.80.12.C174.
7
Glaucoma.青光眼。
Lancet. 2017 Nov 11;390(10108):2183-2193. doi: 10.1016/S0140-6736(17)31469-1. Epub 2017 May 31.
9
Cataracts.白内障。
Lancet. 2017 Aug 5;390(10094):600-612. doi: 10.1016/S0140-6736(17)30544-5. Epub 2017 Feb 25.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验