Bortolotto Chandra, Stella Giulia Maria, Messana Gaia, Lo Tito Antonio, Podrecca Chiara, Nicora Giovanna, Bellazzi Riccardo, Gerbasi Alessia, Agustoni Francesco, Grimm Robert, Zacà Domenico, Filippi Andrea Riccardo, Bottinelli Olivia Maria, Preda Lorenzo
Diagnostic Imaging and Radiotherapy Unit, Department of Clinical, Surgical, Diagnostic, and Pediatric Sciences, University of Pavia, 27100 Pavia, Italy.
Radiology Institute, Fondazione IRCCS Policlinico San Matteo, 27100 Pavia, Italy.
Cancers (Basel). 2022 Nov 16;14(22):5634. doi: 10.3390/cancers14225634.
This study aims to investigate the correlation between intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) parameters in magnetic resonance imaging (MRI) and programmed death-ligand 1 (PD-L1) expression in non-small cell lung cancer (NSCLC). Twenty-one patients diagnosed with stage III NSCLC from April 2021 to April 2022 were included. The tumors were distinguished into two groups: no PD-L1 expression (<1%), and positive PD-L1 expression (≥1%). Conventional MRI and IVIM-DWI sequences were acquired with a 1.5-T system. Both fixed-size ROIs and freehand segmentations of the tumors were evaluated, and the data were analyzed through a software using four different algorithms. The diffusion (D), pseudodiffusion (D*), and perfusion fraction (pf) were obtained. The correlation between IVIM parameters and PD-L1 expression was studied with Pearson correlation coefficient. The Wilcoxon−Mann−Whitney test was used to study IVIM parameter distributions in the two groups. Twelve patients (57%) had PD-L1 ≥1%, and 9 (43%) <1%. There was a statistically significant correlation between D* values and PD-L1 expression in images analyzed with algorithm 0, for fixed-size ROIs (189.2 ± 65.709 µm²/s × 104 in no PD-L1 expression vs. 122.0 ± 31.306 µm²/s × 104 in positive PD-L1 expression, p = 0.008). The values obtained with algorithms 1, 2, and 3 were not significantly different between the groups. The IVIM-DWI MRI parameter D* can reflect PD-L1 expression in NSCLC.
本研究旨在探讨磁共振成像(MRI)中的体素内不相干运动扩散加权成像(IVIM-DWI)参数与非小细胞肺癌(NSCLC)中程序性死亡配体1(PD-L1)表达之间的相关性。纳入了2021年4月至2022年4月期间诊断为III期NSCLC的21例患者。将肿瘤分为两组:无PD-L1表达(<1%)和PD-L1阳性表达(≥1%)。使用1.5-T系统采集常规MRI和IVIM-DWI序列。对肿瘤的固定大小感兴趣区(ROI)和徒手分割均进行了评估,并通过使用四种不同算法的软件对数据进行分析。获得了扩散系数(D)、伪扩散系数(D*)和灌注分数(pf)。采用Pearson相关系数研究IVIM参数与PD-L1表达之间的相关性。使用Wilcoxon-Mann-Whitney检验研究两组中IVIM参数的分布情况。12例患者(57%)的PD-L1≥1%,9例(43%)<1%。对于固定大小的ROI,在使用算法0分析的图像中,D值与PD-L1表达之间存在统计学显著相关性(无PD-L1表达组为189.2±65.709µm²/s×104,PD-L1阳性表达组为122.0±31.306µm²/s×104,p=0.008)。算法1、2和3获得的值在两组之间无显著差异。IVIM-DWI MRI参数D可反映NSCLC中的PD-L1表达。