Chao Tai-Ling, Lee Wen-Hau, Hu Hui-Chun, Lin Yi-Chun, Ho Shu-Yuan, Chen Hui-Hou, Chen Cheng-Pin, Tsai Ya-Min, Fang Jun-Tung, Leong Si-Man, Cheng Yu-Chen, Peng Mavis, Cheng Shu-Hsing, Cheng Chien-Yu, Chang Sui-Yuan
Department of Clinical Laboratory Sciences and Medical Biotechnology, National Taiwan University College of Medicine, Taiwan.
Genomics Research Center, Academia Sinica, Taipei, Taiwan.
J Clin Virol Plus. 2023 Feb;3(1):100133. doi: 10.1016/j.jcvp.2022.100133. Epub 2022 Dec 29.
Although real-time reverse transcriptase polymerase chain reaction (real-time RT-PCR) remains as a golden standard for detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection, it can not be easily expanded to large-scaled screening during outbreaks, and the positive results do not necessarily correlate with infectious status of the identified subjects. In this study, the performance of Vstrip® RV2 COVID-19 Antigen Rapid Test (RAT) and its correlation with virus infectivity was examined by virus culture using 163 sequential respiratory specimens collected from 26 SARS-CoV-2 infected patients. When the presence of cytopathic effects (CPE) in cell culture was used as a reference method for virus infectivity, the sensitivity, specificity and accuracy of Vstrip® RV2 COVID-19 Antigen Rapid Test was 96.43%, 89.63%, and 90.8%, respectively. The highest Ct value was 27.7 for RdRp gene and 25.79 for E gene within CPE-positive samples, and the highest Ct value was 31.9 for RdRp gene and 29.1 for E gene within RAT positive samples. When the Ct values of specimens were below 25, the CPE and RAT results had high degree of consistency. We concluded that the RAT could be a great alternative method for determining the infectious potential of individuals with high viral load.
尽管实时逆转录聚合酶链反应(real-time RT-PCR)仍然是检测严重急性呼吸综合征冠状病毒2(SARS-CoV-2)感染的金标准,但在疫情爆发期间它不易扩展到大规模筛查,而且阳性结果不一定与被检测者的感染状态相关。在本研究中,使用从26名SARS-CoV-2感染患者收集的163份连续呼吸道标本,通过病毒培养检测了Vstrip® RV2 COVID-19抗原快速检测(RAT)的性能及其与病毒传染性的相关性。当细胞培养中细胞病变效应(CPE)的出现作为病毒传染性的参考方法时,Vstrip® RV2 COVID-19抗原快速检测的敏感性、特异性和准确性分别为96.43%、89.63%和90.8%。在CPE阳性样本中,RdRp基因的最高Ct值为27.7,E基因的最高Ct值为25.79;在RAT阳性样本中,RdRp基因的最高Ct值为31.9,E基因的最高Ct值为29.1。当标本的Ct值低于25时,CPE和RAT结果具有高度一致性。我们得出结论,RAT可能是确定病毒载量高的个体感染潜力的一种很好的替代方法。