Suppr超能文献

超声股四头肌厚度与血液透析患者的虚弱程度有关。

Ultrasound quadriceps muscle thickness is variably associated with frailty in haemodialysis recipients.

机构信息

Department of Nephrology and Transplantation, Queen Elizabeth Hospital, Birmingham, B15 2WB, UK.

Institute of Inflammation and Ageing, University of Birmingham, Birmingham, UK.

出版信息

BMC Nephrol. 2023 Jan 18;24(1):16. doi: 10.1186/s12882-022-03043-8.

Abstract

BACKGROUND

Ultrasonographic quantitation of quadriceps muscle mass is increasingly used for assessment of sarcopenia, but its relationship with frailty in haemodialysis recipients is not known. This study explores the relationship between ultrasound-derived bilateral anterior thigh thickness (BATT), sarcopenia, and frailty by common frailty tools (Frailty Phenotype [FP], Frailty Index [FI], Edmonton Frailty [EFS], and Clinical Frailty Scale [CFS]).

METHODS

This was an exploratory analysis of a subgroup of adult prevalent (≥3 months) haemodialysis recipients deeply phenotyped for frailty. Ultrasound assessment of BATT was obtained with participants at an angle of ≤45°, with legs outstretched and knees resting at 10°-20°, according to an established protocol. Associations with frailty were explored via both linear and logistic regressions for BATT, Low Muscle Mass (LMM), and sarcopenia with stepwise adjustment for a priori covariables.

RESULTS

In total 223 study participants had ultrasound measurements. Frailty ranged from 34% for FP to 58% for FI. BATT was associated with increasing frailty on simple linear regression by all frailty tools, but lost significance on addition of covariables. Upon dichotomising frailty tools into Frail/Not Frail, BATT was associated with frailty by all tools on univariable analyses, but only retained association for EFS on the fully adjusted model (OR 0.97, 95% C.I. 0.94-1.00, P = 0.05).

CONCLUSIONS

Ultrasound measures of quadriceps thickness is variably associated with frailty in prevalent haemodialysis recipients, dependent upon the frailty tool used, but not independent of other variables. Further work is required to establish the added value of sarcopenia measurement in frail haemodialysis patients.

TRIAL REGISTRATION

Clinicaltrials.gov : NCT03071107 registered 06/03/2017.

摘要

背景

超声定量股四头肌质量越来越多地用于评估肌肉减少症,但它与血液透析患者的虚弱之间的关系尚不清楚。本研究通过常见的虚弱工具(虚弱表型[FP]、虚弱指数[FI]、埃德蒙顿虚弱[EFS]和临床虚弱量表[CFS])探讨了超声衍生的双侧大腿前厚度(BATT)、肌肉减少症和虚弱之间的关系。

方法

这是对经过深度表型分析的成年血液透析患者亚组的探索性分析。根据既定方案,参与者以≤45°的角度进行 BATT 的超声评估,双腿伸直,膝盖休息在 10°-20°。通过线性和逻辑回归探索 BATT、低肌肉量(LMM)和肌肉减少症与虚弱之间的关联,并根据先验协变量进行逐步调整。

结果

共有 223 名研究参与者进行了超声测量。虚弱程度从 FP 的 34%到 FI 的 58%不等。在所有虚弱工具的简单线性回归中,BATT 与虚弱程度呈正相关,但在加入协变量后失去了意义。在将虚弱工具分为虚弱/不虚弱后,BATT 在单变量分析中与所有工具的虚弱相关,但仅在完全调整模型中与 EFS 保留关联(OR 0.97,95%CI 0.94-1.00,P=0.05)。

结论

超声股四头肌厚度测量与血液透析患者的虚弱程度呈不同程度相关,这取决于所使用的虚弱工具,但与其他变量无关。需要进一步研究以确定在虚弱的血液透析患者中测量肌肉减少症的附加价值。

试验注册

Clinicaltrials.gov:NCT03071107 于 2017 年 3 月 6 日注册。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ed84/9847024/5d7a1d898de9/12882_2022_3043_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验