Suppr超能文献

使用副球孢子菌病患者的储存血清和血浆进行双琼脂凝胶免疫扩散试验的可重复性。

Reproducibility of double agar gel immunodiffusion test using stored serum and plasma from paracoccidioidomycosis patients.

作者信息

Tomazini Karina Andressa, Pereira Beatriz Aparecida Soares, Sylvestre Tatiane Fernanda, Cavalcante Ricardo de Souza, de Carvalho Lídia Raquel, Mendes Rinaldo Poncio

机构信息

Department of Infectology, Dermatology, Diagnostic Imaging and Radiotherapy, Botucatu Medical School (FMB), São Paulo State University (UNESP), Botucatu, SP, Brazil.

Anhanguera School of Bauru, Bauru, SP, Brazil.

出版信息

J Venom Anim Toxins Incl Trop Dis. 2023 Jan 16;29:e20220045. doi: 10.1590/1678-9199-JVATITD-2022-0045. eCollection 2023.

Abstract

BACKGROUND

Serological evaluation performed by double agar gel immunodiffusion test (DID) is used for diagnosis, evaluation of severity, management of paracoccidioidomycosis patients, and development of new clinical studies. For these reasons, the Botucatu Medical School of UNESP maintains a serum bank at the Experimental Research Unit with patient clinical data. This study aimed to evaluate the influence of the freeze-thaw cycle and different blood matrices on the titration of circulating antibodies.

METHODS

The study included 207 patients with confirmed (etiology-demonstrated) or probable (serology-demonstrated) paracoccidioidomycosis, and DID was performed with culture filtrate from B339 as antigen. First experiment: the antibody levels were determined in serum samples from 160 patients with the chronic form and 20 with the acute/subacute form, stored at -80C for more than six months. Second experiment: titers of 81 samples of serum and plasma with ethylenediaminetetraacetic acid (EDTA) or heparin, from 27 patients, were compared according to matrix and effect of storage at -20C for up to six months. Differences of titers higher than one dilution were considered discordant.

RESULTS

First experiment: test and retest presented concordant results in serum stored for up to three years, and discordant titers in low incidence in storage for four to six years but high incidence when stored for more than six years, including conversion from reagent test to non-reagent retest. Second experiment: serum, plasma-EDTA and plasma-heparin samples showed concordant titers, presenting direct correlation, with no interference of storage for up to six months.

CONCLUSIONS

Storage at -80C for up to six years has no or little influence on the serum titers determined by DID, permitting its safe use in studies depending on this parameter. The concordant titrations in different blood matrices demonstrated that the plasma can be used for immunodiffusion test in paracoccidioidomycosis, with stability for at least six months after storage at -20C.

摘要

背景

通过双琼脂凝胶免疫扩散试验(DID)进行的血清学评估用于副球孢子菌病患者的诊断、严重程度评估、管理以及新临床研究的开展。基于这些原因,圣保罗州立大学博图卡图医学院在实验研究单位设有血清库,并保存了患者的临床数据。本研究旨在评估冻融循环和不同血液基质对循环抗体滴定的影响。

方法

该研究纳入了207例确诊(病因证实)或疑似(血清学证实)副球孢子菌病的患者,并以B339的培养滤液作为抗原进行DID检测。第一个实验:测定了160例慢性型患者和20例急性/亚急性型患者的血清样本中的抗体水平,这些样本在-80°C下储存了六个月以上。第二个实验:比较了27例患者的81份含乙二胺四乙酸(EDTA)或肝素的血清和血浆样本在-20°C下储存长达六个月后的基质和储存效果的滴定度。滴定度差异高于一个稀释度被认为是不一致的。

结果

第一个实验:在储存长达三年的血清中,重复检测结果一致,而在储存四至六年时不一致滴定度的发生率较低,但在储存超过六年时发生率较高, 包括从试剂检测转为非试剂复测。第二个实验:血清、EDTA血浆和肝素血浆样本的滴定度一致,呈直接相关性,储存长达六个月无干扰。

结论

在-80°C下储存长达六年对DID测定的血清滴定度没有或几乎没有影响,这使得它可以在依赖此参数的研究中安全使用。不同血液基质中的一致滴定度表明,血浆可用于副球孢子菌病的免疫扩散试验,在-20°C下储存后至少六个月内稳定。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3289/9842191/eeea0f24eeda/1678-9199-jvatitd-29-e20220045-gf1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验