Abstract

In the treatment of ankle fractures, complications such as wound healing problems following open reduction and internal fixation are a major problem. An innovative alternative to this procedure offers a more minimally invasive nail stabilization. The purpose of this biomechanical study was to clarify whether this method was biomechanically comparable to the established method. First, the stability (range of motion, diastasis) and rotational stiffness of the native upper ankle were evaluated in eight pairs of native geriatric specimens. Subsequently, an unstable ankle fracture was created and fixed with a locking plate or a nail in a pairwise manner. The ankles showed significantly less stability and rotational stiffness properties after nail and plate fixations than the corresponding native ankles (p < 0.001 for all parameters). When comparing the two methods, both showed no differences in their range of motion (p = 0.694) and diastasis (p = 0.166). The nail also presented significantly greater rotational stiffness compared to the plate (p = 0.001). However, both fixations remained behind the native stability and rotational stiffness. Due to the comparable biomechanical properties of the nail and plate fixations, an early weight-bearing following nail fixation should be assessed on a case-by-case basis considering the severity of fractures.

摘要

在踝关节骨折的治疗中,切开复位内固定术后出现的诸如伤口愈合问题等并发症是一个主要问题。该手术的一种创新替代方法是提供一种创伤更小的髓内钉固定术。这项生物力学研究的目的是阐明这种方法在生物力学上是否与既定方法相当。首先,在八对老年新鲜标本中评估了正常上踝关节的稳定性(活动范围、分离)和旋转刚度。随后,制造不稳定的踝关节骨折,并以成对方式用锁定钢板或髓内钉进行固定。与相应的正常踝关节相比,髓内钉和钢板固定后的踝关节稳定性和旋转刚度特性明显降低(所有参数p<0.001)。比较这两种方法时,两者在活动范围(p=0.694)和分离(p=0.166)方面均无差异。与钢板相比,髓内钉的旋转刚度也明显更大(p=0.001)。然而,两种固定方式的稳定性和旋转刚度仍低于正常情况。由于髓内钉和钢板固定在生物力学特性上具有可比性,应根据骨折的严重程度逐案评估髓内钉固定后早期负重的情况。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c77b/9862725/d84f7d959049/jcm-12-00698-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验