Suppr超能文献

Electroacoustic calibration for sound field warble tone thresholds.

作者信息

Cox R M, McCormick V A

机构信息

Memphis State University, TN.

出版信息

J Speech Hear Disord. 1987 Nov;52(4):388-92. doi: 10.1044/jshd.5204.388.

Abstract

Walker, Dillon, and Byrne (1984) suggested reference equivalent threshold sound pressure levels (RETSPLs) for warble tones with specific modulation parameter values audited from a test position at the critical distance in a semireverberant sound field. This study evaluated these RETSPLs in two typical audiometric rooms and with typically encountered FM tones. Thresholds were measured under earphones and in two sound fields for 6-11 normal hearers at six test frequencies. Results indicated that there was a small but statistically significant difference between earphone and sound field thresholds in 4 of 24 comparisons. However, in both sound fields, 99% of the sound field thresholds were within 10 dB of the earphone thresholds. It is concluded that these RETSPLs are appropriate for electroacoustic calibration of sound field warble tones similar to those used in this study.