Suppr超能文献

单峰骆驼中健身追踪器(Equimetre)与标准基-尖心电图的比较。

Comparison between a fitness tracker (Equimetre) and standard base-apex electrocardiography in dromedary camels.

作者信息

Al Khamis Taleb, Shawaf Turke, Almubarak Adel, Al-Ali Mohammed Ali

机构信息

Department of Clinical Sciences, College of Veterinary Medicine, King Faisal University, Al-Ahsa, Saudi Arabia.

出版信息

Front Vet Sci. 2023 Jan 12;9:963732. doi: 10.3389/fvets.2022.963732. eCollection 2022.

Abstract

BACKGROUND

Personalized healthcare technology has grown explosively through the use of portable and smart monitoring devices for diagnosis. The objective of this study was to determine the practicality and usability of the Equimetre fitness tracker on camels in comparison to the standard base-apex system in normal and clinical cases.

METHODS

Five apparently healthy adult camels, five clinical adult cases and two clinical calves were enrolled in this study. The camels were equipped with two monitoring systems: Equimetre and a standard base-apex electrocardiogarphy. Each tracing was evaluated for the normal ECG variable's measure, including heart rate beats per min, P-R, QRS, R-R, Q-T, S-T intervals, and P-R and S-T segments in seconds. The amplitudes for P, Q, R, S, and T-peaks were evaluated in millivolts.

RESULTS

Equimetre showed stability on ECG tracing with less movement artifacts compared with the standard base-apex system. Different polarities were observed for the P-waves and T-waves between the standard base-apex system and Equimetre. Both devices showed perfect agreement for heart rate (ICC = 1.00, ≥ 0.0001, 95% = 1.00-1.00) in healthy and clinical adults. A good correlation was observed for the R-R interval between the devices in healthy and clinical adults. A moderate correlation was observed between the devices for Q-peak in clinical adults, with no correlation in clinical calves.

CONCLUSIONS

This study demonstrated acceptable ECG measurements between the standard base-apex and Equimetre device. This suggests that Equimetre could be a useful device in camels for initial electrocardiographic examinations in remote areas such as deserts.

摘要

背景

通过使用便携式和智能监测设备进行诊断,个性化医疗技术得到了迅猛发展。本研究的目的是,在正常和临床病例中,将Equimetre健身追踪器与标准的基底部-心尖部系统相比较,以确定其在骆驼身上的实用性和易用性。

方法

本研究纳入了5头看似健康的成年骆驼、5例临床成年病例和2头临床幼崽。给骆驼配备了两种监测系统:Equimetre和标准的基底部-心尖部心电图仪。对每份心电图记录进行正常心电图变量测量评估,包括每分钟心率、P-R间期、QRS波群、R-R间期、Q-T间期、S-T段间期,以及以秒为单位的P-R段和S-T段。评估P波、Q波、R波、S波和T波峰值的幅度,单位为毫伏。

结果

与标准的基底部-心尖部系统相比,Equimetre在心电图记录上表现出稳定性,运动伪影较少。在标准的基底部-心尖部系统和Equimetre之间,观察到P波和T波的极性不同。在健康和临床成年骆驼中,两种设备在心率方面表现出完美的一致性(组内相关系数=1.00,P≤0.0001,95%置信区间=1.00 - 1.00)。在健康和临床成年骆驼中,两种设备在R-R间期方面具有良好的相关性。在临床成年骆驼中,两种设备在Q波峰值方面具有中等相关性,而在临床幼崽中无相关性。

结论

本研究表明,标准的基底部-心尖部系统和Equimetre设备之间的心电图测量结果是可接受的。这表明Equimetre可能是一种有用的设备,可用于骆驼在沙漠等偏远地区的初始心电图检查。