An alternative generic groundwater-to-indoor air attenuation factor for application in commercial, industrial, and other nonresidential settings.

作者信息

Levy Laurent C, Hallberg Keri E, Gonzalez-Abraham Rodrigo, Lutes Christopher C, Lund Loren G, Caldwell Donna, Walker Teresie R

机构信息

Jacobs Engineering Group Inc, Dallas, TX, USA.

Naval Facilities Engineering Systems Command - Atlantic Division, Norfolk, VA, USA.

出版信息

J Air Waste Manag Assoc. 2023 Apr;73(4):258-270. doi: 10.1080/10962247.2023.2175740. Epub 2023 Mar 2.

Abstract

The default groundwater-to-indoor air attenuation factor (AF) of 10 (0.001) to assess the vapor intrusion (VI) pathway and generate VI screening levels for groundwater was developed by the United States Environmental Protection Agency (EPA) based on chlorinated volatile organic compound (VOC) indoor air and groundwater data collected in residential buildings and compiled in EPA's 2012 VI database. In their VI guidance published in 2015, EPA recognized that this default AF may be overly conservative for nonresidential buildings. In 2015, the Department of Defense (DoD) began developing a first-of-its-kind VI database to assess AFs at commercial and industrial buildings at DoD installations and support the development of alternative generic AF values. This database was expanded in 2019 to include 76 buildings at 22 DoD installations across the United States and is comparable in size to the EPA VI database. The DoD database includes chlorinated VOC data from groundwater and indoor air samples collected from multiple sampling zones within these buildings. Empirical groundwater-to-indoor air AFs were calculated using similar screening methods employed by EPA, including a source strength screen, to filter out potential background source contributions unrelated to VI. Analysis of indoor air-groundwater data pairs found that there is more attenuation occurring from groundwater to indoor air in DoD commercial and industrial buildings relative to residential buildings and that the DoD buildings' AFs are one to four orders of magnitude lower than EPA's residential-based default of 10. The results support the use of a generic groundwater AF of 10 (0.0001) to support VI assessment and develop groundwater screening levels specific to large commercial and industrial buildings as an alternative to the residential default AF.: The use of groundwater-to-indoor air attenuation factors (AFs) is a key component of vapor intrusion (VI) pathway assessments and VI screening-level development for groundwater. Currently, the United States Environmental Protection Agency (EPA) and many state regulatory agencies use a default groundwater AF of 10 (0.001) based on chlorinated volatile organic compound (VOC) data collected in residential buildings. VI assessment data collected at Department of Defense (DoD) installations indicate that there is significantly more groundwater-to-indoor air attenuation occurring at DoD commercial and industrial buildings. For that reason, the default AF of 10 results in groundwater screening levels that are overestimating VI-related risks in these types of building. The DoD data support the use of a generic groundwater AF of 10 (0.0001) for conducting VI assessment and developing groundwater screening levels at large commercial and industrial buildings.

摘要

美国环境保护局(EPA)基于在住宅建筑中收集并汇编于EPA 2012年蒸汽侵入(VI)数据库中的氯化挥发性有机化合物(VOC)室内空气和地下水数据,制定了默认的地下水到室内空气衰减因子(AF)为10(0.001),以评估蒸汽侵入途径并生成地下水的VI筛选水平。在其2015年发布的VI指南中,EPA认识到该默认AF对于非住宅建筑可能过于保守。2015年,美国国防部(DoD)开始开发首个此类VI数据库,以评估国防部设施中商业和工业建筑的AF,并支持制定替代的通用AF值。该数据库在2019年进行了扩展,纳入了美国各地22个国防部设施中的76座建筑,规模与EPA的VI数据库相当。国防部数据库包括从这些建筑内多个采样区域采集的地下水和室内空气样本中的氯化VOC数据。使用EPA采用的类似筛选方法计算了经验性的地下水到室内空气的AF,包括源强筛选以滤除与VI无关的潜在背景源贡献。对室内空气 - 地下水数据对的分析发现,与住宅建筑相比,国防部商业和工业建筑中从地下水到室内空气的衰减更多,并且国防部建筑的AF比EPA基于住宅的默认值10低一到四个数量级。结果支持使用通用的地下水AF为10(0.0001)来支持VI评估,并针对大型商业和工业建筑制定特定的地下水筛选水平,以替代住宅默认AF。:使用地下水到室内空气的衰减因子(AF)是蒸汽侵入(VI)途径评估和地下水VI筛选水平制定的关键组成部分。目前,美国环境保护局(EPA)和许多州监管机构基于在住宅建筑中收集的氯化挥发性有机化合物(VOC)数据,使用默认的地下水AF为10(0.001)。在国防部(DoD)设施收集的VI评估数据表明,国防部商业和工业建筑中从地下水到室内空气的衰减明显更多。因此,默认AF为10导致地下水筛选水平高估了这些类型建筑中与VI相关的风险。国防部的数据支持使用通用的地下水AF为10(0.0001)来进行VI评估并为大型商业和工业建筑制定地下水筛选水平。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验