Suppr超能文献

三维头戴式数字可视化平台在白内障手术中的应用。

Use of a three-dimensional head-mounted digital visualization platform in cataract surgery.

机构信息

Department of Ophthalmology, Tel Aviv Medical Center and Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.

出版信息

Eye (Lond). 2023 Oct;37(14):2905-2908. doi: 10.1038/s41433-023-02427-w. Epub 2023 Feb 3.

Abstract

OBJECTIVE

To report preliminary experience using the BeyeonicsOne (Beyeonics Vision, Haifa, Israel) digital visualization platform and the utilization of its three-dimensional (3D) head-mounted display (HMD) in cataract surgery.

METHODS

An interventional case series including patients who underwent cataract surgery using the 3D HMD platform at the Tel Aviv Medical Center. The system uses the HMD unit to display high-resolution real-time 3D surgical field images. Collected data included patient demographics, ocular comorbidities, risk factors for complex cataract surgery, cataract grading, preoperative and postoperative best-corrected visual acuity (BCVA), and intra- and postoperative complications.

RESULTS

In total, 60 eyes of 60 subjects (mean age 73.1 ± 8.4 years) were included. Mean preoperative BCVA was 0.40 ± 0.30 logMAR (Snellen equivalent ~20/50) and improved to 0.10 ± 0.10 logMAR (Snellen equivalent ~20/25, p < 0.001). None of the patients suffered BCVA loss. All procedures and follow-ups were uneventful except for one case of a posterior capsular tear and one case of post-surgical cystoid macular edema.

CONCLUSION

The visualization platform and its embedded 3D head-mounted display can be easily used in routine cataract surgery with the added benefits of improved ergonomics, high picture quality and enhanced image control.

摘要

目的

报告使用 BeyeonicsOne(Beyeonics Vision,以色列海法)数字可视化平台和其三维(3D)头戴式显示器(HMD)在白内障手术中的初步经验。

方法

本研究为一项介入性病例系列研究,纳入在特拉维夫医疗中心接受 3D HMD 平台辅助下白内障手术的患者。该系统使用 HMD 单元来显示高分辨率实时 3D 手术视野图像。收集的数据包括患者人口统计学特征、眼部合并症、复杂白内障手术的危险因素、白内障分级、术前和术后最佳矫正视力(BCVA)以及术中及术后并发症。

结果

共纳入 60 例 60 只眼(平均年龄 73.1 ± 8.4 岁)。平均术前 BCVA 为 0.40 ± 0.30 logMAR(Snellen 等价物约 20/50),术后提高至 0.10 ± 0.10 logMAR(Snellen 等价物约 20/25,p<0.001)。无一例患者出现 BCVA 下降。除 1 例后囊膜破裂和 1 例术后囊样黄斑水肿外,所有手术和随访均无异常。

结论

该可视化平台及其嵌入式 3D 头戴式显示器可轻松用于常规白内障手术,具有改善的人机工程学、高图像质量和增强的图像控制等优势。