Suppr超能文献

分析角膜特性和密度计对原发性开角型青光眼压平眼压和回弹眼压的影响。

Analysis of the influence of corneal properties and densitometry on applanation and rebound tonometry in primary open angle glaucoma.

机构信息

Hospital Clínico San Carlos, Madrid, Spain.

Hospital Clínico San Carlos, Madrid, Spain.

出版信息

J Fr Ophtalmol. 2023 Mar;46(3):249-257. doi: 10.1016/j.jfo.2022.08.013. Epub 2023 Feb 2.

Abstract

PURPOSE

To evaluate the influence of corneal densitometry on portable applanation (Perkins) and rebound (iCare ic100 and PRO) tonometry. A secondary goal was to assess if there was a relationship between various corneal properties and the severity of primary open angle glaucoma (POAG).

MATERIAL AND METHODS

Seventy-five eyes of 75 patients with primary open angle glaucoma were studied, divided by severity into 3 groups: 25 mild, 25 moderate and 25 advanced. Intraocular pressure (IOP) was measured 3 times in each participant with a Perkins applanation tonometer (PAT), a handheld version of the Goldman applanation tonometer (GAT), an iCare PRO and an iCare ic100. Mean values were then calculated. Corneal topography with the Pentacam HR (Oculus, Wetzlar, Germany) was also performed in all individuals.

RESULTS

Mean age and sex were comparable in all groups, as were densitometry values (P>0.05). The mean visual field defect (MD) was 2.85 (±1.23) dB in the mild glaucoma group, 8.26 (±1.90) dB in the moderate group and 15.66 (±3.46) dB in the advanced group. Three multivariate regression analyses were performed. The first and second calculations assessed the effect of IOP obtained with iCare ic100 and PAT as dependent variables with age, sex, CCT and mean keratometry (Km) within the glaucoma subgroups and the global sample. The third analysis was carried out to assess the relationship between corneal densitometry as the dependant variable and the aforementioned corneal parameters among the glaucoma groups. In the first multivariate regression analysis, a statistically significant correlation was found between ic100 rebound tonometry and CCT in the POAG global sample (coef. 0.117; IC [-0.21-(-0.01)]; P=0.025). No statistically significant correlation was found in the subgroup analyses. In the second multivariate analysis, no significant correlation was found between PAT and CCT, Km, age or sex (P>0.05). In the third analysis, densitometry was correlated with age in all glaucoma subgroups (P<0.001) and with CCT in the moderate glaucoma subgroup (coef. -0.037; IC [-0.67-(-0.01)]; P=0.021). Tonometry appeared to be minimally influenced by corneal densitometry, with a mild positive linear correlation seen (R=0.03). IOP values were similar with 3 of the tonometers: PAT 16.07 (±3.18) mmHg, PRO 16.27 (±3.42) mmHg and ic100 15.17 (±4.28) mmHg. There was, however, a significant underestimation of IOP with ic100 (-0.89mmHg) compared to PAT (P=0.007).

CONCLUSION

Corneal densitometry did not show significant differences between glaucoma severity groups. A positive correlation was seen with CCT and both corneal densitometry and age. No correlation was found with keratometry or severity of glaucoma. The influence of corneal densitometry on IOP measurements appears weak, with little clinical relevance identified.

摘要

目的

评估角膜密度测量对便携式压平( Perkins )和回弹( iCare ic100 和 PRO )眼压计的影响。次要目标是评估各种角膜特性与原发性开角型青光眼( POAG )严重程度之间是否存在关系。

材料和方法

研究了 75 例原发性开角型青光眼患者的 75 只眼,根据严重程度分为 3 组:25 例轻度,25 例中度和 25 例重度。使用 Perkins 压平眼压计( PAT )、手持式 Goldmann 压平眼压计( GAT )、 iCare PRO 和 iCare ic100 对每位参与者进行 3 次眼压测量。然后计算平均值。所有人均进行 Pentacam HR ( Oculus ,德国威茨拉尔)角膜地形图检查。

结果

所有组的平均年龄和性别均相似,密度值也相似( P > 0.05 )。轻度青光眼组的平均视野缺损( MD )为 2.85 ± 1.23dB ,中度组为 8.26 ± 1.90dB ,重度组为 15.66 ± 3.46dB 。进行了 3 次多元回归分析。第一项和第二项计算评估了以 iCare ic100 和 PAT 获得的眼压作为因变量的影响,使用年龄、性别、 CCT 和青光眼亚组及总体样本中的平均角膜曲率( Km )进行评估。第三个分析是为了评估角膜密度与上述各组青光眼患者角膜参数之间的关系。在第一项多元回归分析中,在 POAG 总体样本中发现 ic100 回弹眼压与 CCT 之间存在统计学显著相关性(系数 0.117 ; IC [-0.21-(-0.01 )]; P = 0.025 )。在亚组分析中未发现统计学显著相关性。在第二项多元分析中, PAT 与 CCT 、 Km 、年龄或性别之间未发现显著相关性( P > 0.05 )。在第三个分析中,在所有青光眼亚组中,角膜密度与年龄呈正相关( P < 0.001 ),在中度青光眼亚组中与 CCT 呈正相关(系数 -0.037 ; IC [-0.67-(-0.01 )]; P = 0.021 )。眼压计受角膜密度的影响较小,呈轻度正线性相关( R = 0.03 )。 3 种眼压计的眼压值相似: PAT 16.07 ± 3.18mmHg , PRO 16.27 ± 3.42mmHg 和 ic100 15.17 ± 4.28mmHg 。然而,与 PAT 相比, ic100 ( -0.89mmHg )低估了眼压( P = 0.007 )。

结论

角膜密度在青光眼严重程度组之间没有显著差异。与 CCT 以及角膜密度和年龄均呈正相关。与角膜曲率或青光眼严重程度无相关性。角膜密度对眼压测量的影响似乎较弱,临床意义不大。