Department of Internal Medicine and Clinical Nutrition, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
Praktikertjänst AB, Skövde, 54130, Sweden.
Br J Nutr. 2023 Oct 28;130(8):1289-1297. doi: 10.1017/S0007114523000326. Epub 2023 Feb 6.
Iodine deficiency may cause thyroid dysfunction. The iodine intake in a population is measured by urinary iodine concentration (UIC) in spot samples or 24-h urinary iodine excretion (24UIE). 24UIE is considered the gold standard and may be estimated using an equation including UIC, urinary creatinine concentration, sex and age (e24UIE). The aims of this study were to evaluate the preferable timing of UIC when using this equation and assess the variability of UIE. Sixty healthy non-smoking women ( 31) and men ( 29) were included in Gothenburg, Sweden. Twelve urine samples were collected at six fixed times on two separate days. Variability was calculated for UIC, 24UIE, e24UIE, iodine excretion per hour (iHr) and UIC adjusted for creatinine and specific gravity. Median 24UIE was 156 µg/24 h and the median UIC (all spot samples) was 104 µg/l. UIC ( < 0·001), 24UIE ( = 0·001) and e24UIE ( < 0·001) were significantly higher in men. e24UIE was relatively similar to 24UIE. However, when e24UIE was calculated from UIC in the first void, it was about 15 % lower than 24UIE ( < 0·001). iHr was lowest in the morning and highest in the afternoon. Median iHr was higher in men (7·4 . 5·3 µg/h, < 0·001). The variability of UIE was higher within individuals than between individuals. This study suggests that most time points for estimation of individual 24UIE are appropriate, but they should preferably not be collected in the first void.
碘缺乏可能导致甲状腺功能障碍。人群的碘摄入量通过尿碘浓度(UIC)的单次样本或 24 小时尿碘排泄量(24UIE)来测量。24UIE 被认为是金标准,可通过包括 UIC、尿肌酐浓度、性别和年龄在内的方程进行估计(e24UIE)。本研究的目的是评估使用该方程时 UIC 的最佳时间,并评估 UIE 的变异性。在瑞典哥德堡纳入了 60 名健康不吸烟的女性(31 名)和男性(29 名)。在两天的六个固定时间收集了 12 个尿液样本。计算了 UIC、24UIE、e24UIE、每小时碘排泄量(iHr)和肌酐和比重调整后的 UIC 的变异性。24UIE 的中位数为 156 µg/24 h,UIC(所有单次样本)的中位数为 104 µg/l。男性的 UIC(<0·001)、24UIE(=0·001)和 e24UIE(<0·001)显著更高。e24UIE 与 24UIE 相对相似。然而,当从首次晨尿 UIC 计算 e24UIE 时,其比 24UIE 低约 15%(<0·001)。iHr 早晨最低,下午最高。男性的 iHr 中位数较高(7·4. 5·3 µg/h,<0·001)。UIE 的个体内变异性高于个体间变异性。本研究表明,估计个体 24UIE 的大多数时间点都是合适的,但最好不要在首次晨尿中采集。