Suppr超能文献

Chemcatcher®被动采样器的校准以及通用采样率的推导,以便在地表水监测中广泛应用。

Calibration of the Chemcatcher® passive sampler and derivation of generic sampling rates for a broad application in monitoring of surface waters.

作者信息

Römerscheid Mara, Paschke Albrecht, Schneider Selma, Blaha Maximilian, Harzdorf Julia, Schüürmann Gerrit

机构信息

UFZ Department of Ecological Chemistry, Helmholtz Centre for Environmental Research, Permoserstr. 15, 04318 Leipzig, Germany; Institute of Organic Chemistry, Technical University Bergakademie Freiberg, Leipziger Str. 29, 09599 Freiberg, Germany.

UFZ Department of Ecological Chemistry, Helmholtz Centre for Environmental Research, Permoserstr. 15, 04318 Leipzig, Germany.

出版信息

Sci Total Environ. 2023 May 1;871:161936. doi: 10.1016/j.scitotenv.2023.161936. Epub 2023 Feb 4.

Abstract

We determined sampling rates for 34 pesticides, five pesticide transformation products, and 34 pharmaceutical compounds with the Chemcatcher (CC) passive sampler in a laboratory-based continuous-flow system at 40 cm/s and ambient temperature. Three different sampling phases were used: styrene divinylbenzene disks (SDB-XC), styrene divinylbenzene reversed phase sulfonate disks (SDB-RPS), and hydrophilic lipophilic balance disks (HLB), in all cases covered with a diffusion-limiting polyethersulfone membrane. The measured sampling rates range from 0.007 L/d to 0.193 L/d for CC with SDB-XC (CC-XC), from 0.055 L/d to 0.796 L/d for CC with SDB-RPS (CC-RPS), and from 0.018 L/d to 0.073 L/d for CC equipped with HLB (CC-HLB). Comparison with sampling rates from literature enabled to derive generic sampling rates that can be used for compounds with unknown uptake kinetics such as transformations products and new compounds of interest. Field trial results demonstrate that the presently derived generic sampling rates are suitable for estimating time-weighted average concentrations within reasonable uncertainty limits. In this way, Chemcatcher passive sampling can be applied approximately to a broad range of solutes without the need for deriving compound-specific sampling rates, which enable compliance checks against environmental quality standards and further risk assessment.

摘要

我们在基于实验室的连续流动系统中,于40厘米/秒的流速和环境温度下,使用Chemcatcher(CC)被动采样器测定了34种农药、5种农药转化产物和34种药物化合物的采样率。使用了三种不同的采样阶段:苯乙烯二乙烯基苯盘(SDB-XC)、苯乙烯二乙烯基苯反相磺酸盐盘(SDB-RPS)和亲水亲油平衡盘(HLB),在所有情况下均覆盖有扩散限制聚醚砜膜。对于配备SDB-XC的CC(CC-XC),测得的采样率范围为0.007升/天至0.193升/天;对于配备SDB-RPS的CC(CC-RPS),采样率范围为0.055升/天至0.796升/天;对于配备HLB的CC(CC-HLB),采样率范围为0.018升/天至0.073升/天。与文献中的采样率进行比较,得以推导出通用采样率,可用于摄取动力学未知的化合物,如转化产物和新的目标化合物。现场试验结果表明,目前推导的通用采样率适用于在合理的不确定度范围内估算时间加权平均浓度。通过这种方式,Chemcatcher被动采样可大致应用于广泛的溶质,而无需推导特定化合物的采样率,这有助于对照环境质量标准进行合规检查和进一步的风险评估。