Suppr超能文献

氮化钛涂层与未涂层骨水泥型活动轴承全膝关节置换术中期随访的临床差异:一项配对队列研究

No clinical difference at mid-term follow-up between TiN-coated versus uncoated cemented mobile-bearing total knee arthroplasty: a matched cohort study.

作者信息

Deroche Etienne, Batailler Cécile, Shatrov Jobe, Gunst Stanislas, Servien Elvire, Lustig Sébastien

机构信息

Orthopaedic Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, 69004 Lyon, France.

Sydney Orthopaedic Research Institute (SORI) at Landmark Orthopaedics, 500 Pacific Hwy, St. Leonards, NSW, Australia.

出版信息

SICOT J. 2023;9:5. doi: 10.1051/sicotj/2023001. Epub 2023 Feb 9.

Abstract

INTRODUCTION

Nitride-based ceramic coating was introduced into surgical implants to improve hardness, reduce abrasion, and decrease the risk of metal-induced adverse reactions, especially for patients with suspected or identified metal hypersensitivity. The study aimed to evaluate the effectiveness and safety of a titanium nitride (TiN) coated prosthesis with a mobile bearing design.

METHODS

This was a retrospective matched-cohort study from a single center, comparing clinical outcomes between patients receiving either a TiN-coated versus an uncoated cobalt-chromium-molybdenum (CoCrMo) prostheses for primary total knee replacement. Seventeen patients received the TiN prosthesis between 2015 and 2019. These were matched 1:2 with patients receiving uncoated mobile-bearing knee prostheses with the same design manufacturer.

RESULTS

Fourteen patients in the TiN group had complete 5-year follow-up data and were compared with 34 patients from the CoCrMo group. The Knee Society Score was 170.6 ± 28.0 (Function subscore 83.7 ± 17.5 and Knee subscore 86.9 ± 13.8) in the TiN group and 180.7 ± 49.4 (Function subscore 87.5 ± 14.3 and Knee subscore 93.2 ± 9.6) in CoCrMo group, with no statistically significant difference (p = 0.19). One patient underwent a revision for instability requiring the removal of the implant in the TiN group and none in the CoCrMo group. The survival rates were 92.9% (CI95% 77.3-100.0) and 100.0% in the TiN group and CoCrMo group respectively (p = 1.0).

DISCUSSION

TiN-coated TKA with mobile bearing resulted in satisfactory clinical outcomes, and a low revision rate, and there was no complication related to the coated implant. The use of TiN-coated prostheses in case of confirmed or suspected metal allergy provides satisfactory short-term clinic outcomes.

摘要

引言

基于氮化物的陶瓷涂层被引入外科植入物,以提高硬度、减少磨损并降低金属诱导的不良反应风险,特别是对于疑似或已确诊金属过敏的患者。本研究旨在评估具有活动轴承设计的氮化钛(TiN)涂层假体的有效性和安全性。

方法

这是一项来自单一中心的回顾性匹配队列研究,比较接受TiN涂层与未涂层的钴铬钼(CoCrMo)假体进行初次全膝关节置换的患者的临床结果。2015年至2019年间,17名患者接受了TiN假体。这些患者与接受相同设计制造商的未涂层活动轴承膝关节假体的患者按1:2进行匹配。

结果

TiN组有14名患者获得了完整的5年随访数据,并与CoCrMo组的34名患者进行了比较。TiN组的膝关节协会评分是170.6±28.0(功能子评分83.7±17.5,膝关节子评分86.9±13.8),CoCrMo组为180.7±49.4(功能子评分87.5±14.3,膝关节子评分93.2±9.6),差异无统计学意义(p = 0.19)。TiN组有1名患者因不稳定进行了翻修,需要取出植入物,而CoCrMo组没有。TiN组和CoCrMo组的生存率分别为92.9%(CI95% 77.3 - 100.0)和100.0%(p = 1.0)。

讨论

具有活动轴承的TiN涂层全膝关节置换术产生了令人满意的临床结果和较低的翻修率,并且没有与涂层植入物相关的并发症。在确诊或疑似金属过敏的情况下使用TiN涂层假体可提供令人满意的短期临床结果。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a5f8/9910165/c7e36c647554/sicotj-9-5-fig1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验