Suppr超能文献

30秒坐立试验作为多发性硬化症患者下肢功能测量方法的有效性:初步证据。

Validity of the 30-Second Sit-to-Stand test as a measure of lower extremity function in persons with multiple sclerosis: Preliminary evidence.

作者信息

Zheng Peixuan, Huynh Trinh L T, Jones C Danielle, Feasel Corey D, Jeng Brenda, Motl Robert W

机构信息

Department of Kinesiology and Nutrition, College of Applied Health Sciences, University of Illinois Chicago, 1919W. Taylor St., Chicago, IL 60612, USA.

Department of Physical Therapy, School of Health Professions, University of Alabama at Birmingham, Birmingham, AL, USA.

出版信息

Mult Scler Relat Disord. 2023 Mar;71:104552. doi: 10.1016/j.msard.2023.104552. Epub 2023 Feb 5.

Abstract

BACKGROUND

The 30-Second Sit-To-Stand (30SSTS) is a quick, inexpensive, safe, and widely used clinical measure of lower extremity function. To date, there is limited evidence regarding the use of 30SSTS in multiple sclerosis (MS). The purpose of this study was to examine the construct validity of the 30SSTS test in persons with MS compared with non-MS healthy controls.

METHODS

Twenty ambulatory persons with MS and twenty age- and sex-matched healthy controls completed the 30SSTS, Timed 25-Foot Walk (T25FW), Timed Up and Go (TUG), Six-Minute Walk (6MW), and Godin Leisure-Time Exercise Questionnaire (GLTEQ). Persons with MS also completed the Patient Determined Disease Steps (PDDS) and 12-item MS Walking Scale (MSWS-12).

RESULTS

Persons with MS had significantly worse performance on the TUG (mean difference [95% confidence interval] = 1.4 [0.5, 2.3] sec) and 6MW (-259.2 [-450.8, -67.6] ft), but not on the 30SSTS (-1.6 [-1.5, 4.6] reps) and T25FW (-0.59 [-0.1, 1.2] ft/sec) compared with controls. There were significant moderate-to-strong correlations between the 30SSTS with T25FW, TUG, and 6MW scores in persons with MS (r = 0.48, -0.65 and 0.61, respectively), whereas the 30SSTS was only significantly associated with 6MW scores (r = 0.43) in controls. The 30SSTS was negatively associated with MS-related walking disability assessed by the PDDS and MSWS-12 (r = -0.52 and -0.64, respectively), but was not significantly associated with the GLTEQ in MS and controls (r = 0.30 and 0.17, respectively).

CONCLUSION

This study provides initial support for the construct validity of the 30SSTS as a measure of lower extremity function in persons with MS. Our findings warrant the inclusion of the 30SSTS as a feasible and valid measure of physical function in clinical research and practice involving persons with MS.

摘要

背景

30秒坐立试验(30SSTS)是一种快速、廉价、安全且广泛应用的下肢功能临床检测方法。迄今为止,关于30SSTS在多发性硬化症(MS)中的应用证据有限。本研究的目的是检验与非MS健康对照相比,30SSTS测试在MS患者中的结构效度。

方法

20名能行走的MS患者和20名年龄及性别匹配的健康对照完成了30SSTS、25英尺定时步行试验(T25FW)、起立行走试验(TUG)、6分钟步行试验(6MW)以及戈丁休闲时间运动问卷(GLTEQ)。MS患者还完成了患者自评疾病步速(PDDS)和12项MS步行量表(MSWS - 12)。

结果

与对照组相比,MS患者在TUG(平均差异[95%置信区间]=1.4[0.5, 2.3]秒)和6MW(-259.2[-450.8, -67.6]英尺)上的表现显著更差,但在30SSTS(-1.6[-1.5, 4.6]次重复)和T25FW(-0.59[-0.1, 1.2]英尺/秒)上无差异。在MS患者中,30SSTS与T25FW、TUG和6MW得分之间存在显著的中度至强相关性(r分别为0.48、-0.65和0.61),而在对照组中,30SSTS仅与6MW得分显著相关(r = 0.43)。30SSTS与通过PDDS和MSWS - 12评估的MS相关步行障碍呈负相关(r分别为-0.52和-0.64),但与MS患者及对照组的GLTEQ无显著相关性(r分别为0.30和0.17)。

结论

本研究为30SSTS作为MS患者下肢功能测量方法的结构效度提供了初步支持。我们的研究结果表明,在涉及MS患者的临床研究和实践中,应将30SSTS作为一种可行且有效的身体功能测量方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验