Suppr超能文献

不同导板辅助下混合目标修复空间型贴面预备深度的准确性:一项体外研究。

Accuracy of the preparation depth in mixed targeted restorative space type veneers assisted by different guides: An in vitro study.

作者信息

Gao Jing, Luo Tian, Zhao Yuwei, Xie Chenyang, Yu Haiyang

机构信息

State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Disease, West China Hospital of Stomatology, Sichuan University, Chengdu, China.

出版信息

J Prosthodont Res. 2023 Oct 13;67(4):556-561. doi: 10.2186/jpr.JPR_D_22_00229. Epub 2023 Feb 11.

Abstract

PURPOSE

Most veneers are mixed targeted restorative space (MTRS)-type restorations that are partially within the original tooth and require inconsistent preparation depths. This study aimed to evaluate the accuracy of the preparation depth for MTRS veneer preparation.

METHODS

MTRS veneer preparation models were developed using the twisted maxillary central incisor (MCI) as the original tooth and the standard MCI as the waxing. Veneer preparations were performed using freehand (MF), silicone (MS), thermoplastic (MT), 3D-printed uniform (MD), and auto-stop (MA) guides. The prepared and original MCI were scanned and superimposed using a custom-made base. The mean absolute differences (MADs) were measured to evaluate the accuracy of the preparation depth. Statistical analysis was performed using the multivariate analysis of variance (MANOVA) test (α=0.05).

RESULTS

The accuracy of the preparation depth was 0.237±0.090, 0.191±0.099, 0.149±0.078, 0.093±0.050, and 0.059±0.040 mm in MF, MS, MT, MD, and MA, respectively. The MADs between the groups were significant (P<0.05). The accuracy of the trial restoration was 0.140±0.081 mm in the MS, and the accuracy of the guiding tube was 0.055±0.033, 0.036±0.011, and 0.033±0.010 mm in the MT, MD, and MA, respectively.

CONCLUSIONS

In MTRS veneer preparation for MCI, tooth preparation guides improved the accuracy of the preparation depth by visualizing the TRS profile and providing clear measurement points. The accuracy of the guide is influenced by its flexibility, and the accuracy of the preparation depth is affected by the accuracy of the measurement points.

摘要

目的

大多数贴面属于混合目标修复间隙(MTRS)型修复体,部分位于原牙内部,且所需的预备深度不一致。本研究旨在评估MTRS贴面预备的预备深度准确性。

方法

以扭转的上颌中切牙(MCI)作为原牙,标准MCI作为蜡型,制作MTRS贴面预备模型。使用徒手(MF)、硅橡胶(MS)、热塑性材料(MT)、3D打印均匀厚度(MD)和自动停止(MA)导板进行贴面预备。使用定制基座对预备后的和原始的MCI进行扫描并叠加。测量平均绝对差值(MAD)以评估预备深度的准确性。采用多因素方差分析(MANOVA)检验进行统计分析(α=0.05)。

结果

MF、MS、MT、MD和MA组的预备深度准确性分别为0.237±0.090、0.191±0.099、0.149±0.078、0.093±0.050和0.059±0.040mm。各组之间的MAD有显著性差异(P<0.05)。MS组试戴修复体的准确性为0.140±0.081mm,MT、MD和MA组导板管的准确性分别为0.055±0.033、0.036±0.011和0.033±0.010mm。

结论

在对MCI进行MTRS贴面预备时,牙齿预备导板通过可视化TRS轮廓并提供清晰的测量点,提高了预备深度的准确性。导板的准确性受其柔韧性影响,而预备深度的准确性受测量点准确性的影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验