Helmsley Electrophysiology Center, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, PO Box 1030, New York, NY 10029, USA.
Homolka Hospital, Prague, Czech Republic.
Europace. 2023 Apr 15;25(4):1369-1378. doi: 10.1093/europace/euad030.
Single-shot pulmonary vein isolation can improve procedural efficiency. To assess the capability of a novel, expandable lattice-shaped catheter to rapidly isolate thoracic veins using pulsed field ablation (PFA) in healthy swine.
The study catheter (SpherePVI; Affera Inc) was used to isolate thoracic veins in two cohorts of swine survived for 1 and 5 weeks. In Experiment 1, an initial dose (PULSE2) was used to isolate the superior vena cava (SVC) and the right superior pulmonary vein (RSPV) in six swine and the SVC only in two swine. In Experiment 2, a final dose (PULSE3) was used for SVC, RSPV, and left superior pulmonary vein (LSPV) in five swine. Baseline and follow-up maps, ostial diameters, and phrenic nerve were assessed. Pulsed field ablation was delivered atop the oesophagus in three swine. All tissues were submitted for pathology. In Experiment 1, all 14/14 veins were isolated acutely with durable isolation demonstrated in 6/6 RSPVs and 6/8 SVC. Both reconnections occurred when only one application/vein was used. Fifty-two and 32 sections from the RSPVs and SVC revealed transmural lesions in 100% with a mean depth of 4.0 ± 2.0 mm. In Experiment 2, 15/15 veins were isolated acutely with 14/15 veins (5/5 SVC, 5/5 RSPV, and 4/5 LSPV) durably isolated. Right superior pulmonary vein (31) and SVC (34) sections had 100% transmural, circumferential ablation with minimal inflammation. Viable vessels and nerves were noted without evidence of venous stenosis, phrenic palsy, or oesophageal injury.
This novel expandable lattice PFA catheter can achieve durable isolation with transmurality and safety.
单次肺静脉隔离可以提高手术效率。评估一种新型可扩张格状导管在健康猪中使用脉冲场消融(PFA)快速隔离胸静脉的能力。
研究导管(SpherePVI;Affera Inc)用于在存活 1 周和 5 周的两组猪中隔离胸静脉。在实验 1 中,初始剂量(PULSE2)用于隔离 6 只猪的上腔静脉(SVC)和右肺上静脉(RSPV),以及 2 只猪的 SVC 仅。在实验 2 中,最终剂量(PULSE3)用于 5 只猪的 SVC、RSPV 和左肺上静脉(LSPV)。评估基线和随访图、口部直径和膈神经。在 3 只猪的食道顶部施加脉冲场消融。所有组织均提交进行病理学检查。在实验 1 中,14/14 条静脉均被急性隔离,6/6 的 RSPV 和 6/8 的 SVC 显示出持久的隔离。两次再通均发生在仅使用一次应用/静脉时。RSPV 和 SVC 的 52 个和 32 个切片显示出 100%的透壁病变,平均深度为 4.0±2.0mm。在实验 2 中,15/15 条静脉被急性隔离,14/15 条静脉(5/5 SVC、5/5 RSPV 和 4/5 LSPV)持久隔离。右肺上静脉(31 个)和 SVC(34 个)切片具有 100%的透壁、环周消融,炎症最小。观察到有活力的血管和神经,没有静脉狭窄、膈神经麻痹或食道损伤的证据。
这种新型可扩张格状 PFA 导管可以实现持久的隔离,具有透壁性和安全性。