使用超声成像评估腰椎多裂肌大小、形状和质量指标时身体成分与检查者间误差的相关性

Correlation between Body Composition and Inter-Examiner Errors for Assessing Lumbar Multifidus Muscle Size, Shape and Quality Metrics with Ultrasound Imaging.

作者信息

Varol Umut, Sánchez-Jiménez Elena, Leloup Emma Alyette Adélaïde, Navarro-Santana Marcos José, Fernández-de-Las-Peñas César, Sánchez-Jorge Sandra, Valera-Calero Juan Antonio

机构信息

Escuela Internacional de Doctorado, Universidad Rey Juan Carlos, 29222 Alcorcón, Spain.

Faculty of Health, Universidad Católica de Ávila, C/Canteros, s/n, 05005 Ávila, Spain.

出版信息

Bioengineering (Basel). 2023 Jan 18;10(2):133. doi: 10.3390/bioengineering10020133.

Abstract

Ultrasound imaging (US) is widely used in several healthcare disciplines (including physiotherapy) for assessing multiple muscle metrics such as muscle morphology and quality. Since measuring instruments are required to demonstrate their reliability, accuracy, sensitivity, and specificity prior to their use in clinical and research settings, identifying factors affecting their diagnostic accuracy is essential. Since previous studies analyzed the impact of sociodemographic but not body composition characteristics in US errors, this study aimed to assess whether body composition metrics are correlated with ultrasound measurement errors. B-mode images of the lumbar multifidus muscle at the fifth lumbar vertebral level (L5) were acquired and analyzed in 49 healthy volunteers by two examiners (one experienced and one novel). Cross-sectional area, muscle perimeter and mean echo intensity were calculated bilaterally. A multivariate correlation matrix was calculated for assessing the inter-examiner differences with body composition metrics. Results demonstrated excellent reliability (intraclass correlation coefficient, ICC > 0.9) for assessing the muscle cross-sectional area and perimeter, and good reliability for assessing the muscle shape and mean echo intensity (ICC > 0.7). Inter-examiner errors for estimating muscle size were correlated with participants' age ( value, < 0.01), weight ( < 0.05), total and trunk lean mass (both, < 0.01) and water volume ( < 0.05). Greater shape descriptors and mean brightness disagreements were correlated with older ages ( < 0.05) and total lean mass ( < 0.05). No correlations between age and body composition metrics were found ( > 0.05). This study found US to be a reliable tool for assessing muscle size, shape and mean brightness. Although aging showed no correlations with body composition changes in this sample, it was the main factor correlated with US measurement errors.

摘要

超声成像(US)在包括物理治疗在内的多个医疗保健学科中被广泛用于评估多种肌肉指标,如肌肉形态和质量。由于测量仪器在临床和研究环境中使用之前需要证明其可靠性、准确性、敏感性和特异性,因此识别影响其诊断准确性的因素至关重要。由于先前的研究分析了社会人口统计学因素对超声测量误差的影响,而非身体成分特征的影响,本研究旨在评估身体成分指标是否与超声测量误差相关。两名检查人员(一名经验丰富,一名新手)对49名健康志愿者的第五腰椎水平(L5)的腰多裂肌进行了B模式图像采集和分析。双侧计算横截面积、肌肉周长和平均回声强度。计算多变量相关矩阵以评估检查人员之间在身体成分指标方面的差异。结果表明,在评估肌肉横截面积和周长方面具有出色的可靠性(组内相关系数,ICC>0.9),在评估肌肉形状和平均回声强度方面具有良好的可靠性(ICC>0.7)。估计肌肉大小的检查人员间误差与参与者的年龄( 值,<0.01)、体重(<0.05)、全身和躯干瘦体重(两者均<0.01)以及水量(<0.05)相关。更大的形状描述符和平均亮度差异与年龄较大(<0.05)和全身瘦体重(<0.05)相关。未发现年龄与身体成分指标之间存在相关性(>0.05)。本研究发现超声是评估肌肉大小、形状和平均亮度的可靠工具。尽管在本样本中衰老与身体成分变化无相关性,但它是与超声测量误差相关的主要因素。