一种使用超声成像测量前斜角肌形态和质量的方法:一项内部和外部评估者可靠性研究。

A Procedure for Measuring Anterior Scalene Morphology and Quality with Ultrasound Imaging: An Intra- and Inter-rater Reliability Study.

机构信息

Department of Radiology, Rehabilitation and Physiotherapy, Universidad Complutense de Madrid, Madrid, Spain; Grupo In Physio, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Madrid, Spain.

Faculty of Health, Universidad Católica de Ávila, Ávila, Spain.

出版信息

Ultrasound Med Biol. 2023 Aug;49(8):1817-1823. doi: 10.1016/j.ultrasmedbio.2023.04.005. Epub 2023 May 13.

Abstract

OBJECTIVE

Ultrasound (US) imaging is an essential tool for clinicians because of its cost-effectiveness and accessibility for assessing multiple muscle metrics including muscle quality, size and shape. Although previous studies highlighted the importance of the anterior scalene muscle (AS) in patients with neck pain, studies analyzing the reliability of US measurements for this muscle are lacking. This study aimed to develop a protocol for assessing AS muscle shape and quality measured with US and investigating its intra- and inter-examiner reliability.

METHODS

Through use of a linear transducer, B-mode images of the anterolateral neck region at the C7 level were acquired in 28 healthy volunteers by two examiners (one experienced and one novel). Cross-sectional area, perimeter, shape descriptors and mean echo-intensity were measured twice by each examiner in randomized order. Intra-class correlation coefficients (ICCs), standard errors of measurement and minimal detectable changes were calculated.

RESULTS

Results indicated no muscle side-to-side asymmetries (p > 0.05). Gender differences were found for muscle size (p < 0.01), but muscle shape and brightness were comparable (p > 0.05). Intra-examiner reliability was good to excellent for all metrics for the experienced and (ICC >0.846) and novel (ICC >780) examiners. Although inter-examiner reliability was good for most of the metrics (ICC >0.709), the estimates for assessing solidity and circularity were unacceptable (ICC <0.70).

CONCLUSION

This study found that the described ultrasound procedure for locating and measuring anterior scalene muscle morphology and quality is highly reliable in asymptomatic individuals.

摘要

目的

超声(US)成像因其具有成本效益且易于获取,可用于评估包括肌肉质量、大小和形状在内的多种肌肉指标,因此是临床医生的重要工具。尽管先前的研究强调了前斜角肌(AS)在颈痛患者中的重要性,但缺乏分析该肌肉 US 测量可靠性的研究。本研究旨在制定一种使用 US 评估 AS 肌肉形态和质量的方案,并研究其内部和外部检验者的可靠性。

方法

通过使用线性换能器,由两位检查者(一位有经验,一位无经验)在 28 名健康志愿者的 C7 水平前外侧颈部区域采集 B 模式图像。通过每位检查者两次以随机顺序测量横截面积、周长、形状描述符和平均回波强度。计算了组内相关系数(ICC)、测量标准误差和最小可检测变化。

结果

结果表明没有肌肉的左右不对称(p > 0.05)。检查者发现肌肉大小存在性别差异(p < 0.01),但肌肉形状和亮度相当(p > 0.05)。对于有经验的检查者(ICC >0.846)和无经验的检查者(ICC >780),所有指标的内部检查者可靠性均为良好至优秀。尽管大多数指标的外部检查者可靠性良好(ICC >0.709),但评估坚固性和圆形度的估计值不可接受(ICC <0.70)。

结论

本研究发现,用于定位和测量前斜角肌形态和质量的描述性超声程序在无症状个体中具有高度可靠性。