Suppr超能文献

基于环保合成碳点荧光猝灭的顺序注射分析法快速测定护肤品中的汞

Sequential Injection Analysis for Rapid Determination of Mercury in Skincare Products Based on Fluorescence Quenching of Eco-Friendly Synthesized Carbon Dots.

作者信息

Sakunrungrit Kanokwan, Suwanchawalit Cheewita, Charoenkitamorn Kanokwan, Hongwitayakorn Apisake, Strzelak Kamil, Chaneam Sumonmarn

机构信息

Department of Chemistry, Faculty of Science, Silpakorn University, Nakhon Pathom 73000, Thailand.

Department of Computing, Faculty of Science, Silpakorn University, Nakhon Pathom 73000, Thailand.

出版信息

ACS Omega. 2023 Feb 14;8(8):7615-7625. doi: 10.1021/acsomega.2c07175. eCollection 2023 Feb 28.

Abstract

This work reports the analysis of mercury using a spectrofluorometric method combined with a sequential injection analysis (SIA) system. This method is based on the measurement of fluorescence intensity of carbon dots (CDs), which is quenched proportionally after adding mercury ions. Herein, the CDs underwent environmentally friendly synthesis using a microwave-assisted approach that provides intensive and efficient energy and shortens reaction time. After irradiation at 750 W for 5 min in a microwave oven, a dark brown CD solution with a concentration of 2.7 mg mL was obtained. The properties of the CDs were characterized by transmission electron microscopy, X-ray diffractometry, X-ray photoelectron spectroscopy, Fourier-transform infrared spectroscopy, and UV-vis spectrometry. We presented for the first time the use of CDs as a specific reagent for the determination of mercury in skincare products with the SIA system to achieve rapid analysis and full automatic control. The as-prepared CD stock solution was diluted 10 times and used as a reagent in the SIA system. Excitation and emission wavelengths at 360 and 452 nm, respectively, were used to construct a calibration curve. Physical parameters affecting the SIA performance were optimized. In addition, the effect of pH and other ions was investigated. Under the optimum conditions, our method showed a linear range from 0.3 to 600 mg L with an of 0.99. The limit of detection was 0.1 mg L. Relative standard deviation was 1.53% ( = 12) with a high sample throughput of 20 samples per hour. Finally, the accuracy of our method was validated by comparison using inductively coupled plasma mass spectrometry. Acceptable recoveries were also presented without a significant matrix effect. This method was also the first time that uses the untreated CDs for the determination of mercury(II) in skincare products. Therefore, this method could be an alternative for mercuric toxic control in other sample applications.

摘要

本工作报道了一种结合顺序注射分析(SIA)系统的荧光光谱法用于汞分析。该方法基于对碳点(CDs)荧光强度的测量,加入汞离子后荧光强度会成比例猝灭。在此,采用微波辅助方法对CDs进行了环境友好型合成,该方法能提供高强度和高效的能量并缩短反应时间。在微波炉中以750 W照射5分钟后,得到了浓度为2.7 mg/mL的深棕色CD溶液。通过透射电子显微镜、X射线衍射、X射线光电子能谱、傅里叶变换红外光谱和紫外可见光谱对CDs的性质进行了表征。我们首次展示了使用CDs作为特定试剂,结合SIA系统用于测定护肤品中的汞,以实现快速分析和全自动控制。将所制备的CD储备溶液稀释10倍后用作SIA系统中的试剂。分别使用360和452 nm的激发和发射波长构建校准曲线。对影响SIA性能的物理参数进行了优化。此外,研究了pH值和其他离子的影响。在最佳条件下,我们的方法线性范围为0.3至600 mg/L,相关系数为0.99。检测限为0.1 mg/L。相对标准偏差为1.53%(n = 12),每小时样品通量高达20个。最后,通过与电感耦合等离子体质谱法比较验证了我们方法的准确性。还给出了可接受的回收率且无明显基质效应。该方法也是首次使用未经处理的CDs测定护肤品中的汞(II)。因此,该方法可作为其他样品应用中汞毒性控制的一种替代方法。