Abstract

PURPOSE

To compare the residual range of motion (ROM) of cortical screw (CS) versus pedicle screw (PS) instrumented lumbar segments and the additional effect of transforaminal interbody fusion (TLIF) and cross-link (CL) augmentation.

METHODS

ROM of thirty-five human cadaver lumbar segments in flexion/extension (FE), lateral bending (LB), lateral shear (LS), anterior shear (AS), axial rotation (AR), and axial compression (AC) was recorded. After instrumenting the segments with PS (n = 17) and CS (n = 18), ROM in relation to the uninstrumented segments was evaluated without and with CL augmentation before and after decompression and TLIF.

RESULTS

CS and PS instrumentations both significantly reduced ROM in all loading directions, except AC. In undecompressed segments, a significantly lower relative (and absolute) reduction of motion in LB was found with CS 61% (absolute 3.3°) as compared to PS 71% (4.0°; p = 0.048). FE, AR, AS, LS, and AC values were similar between CS and PS instrumented segments without interbody fusion. After decompression and TLIF insertion, no difference between CS and PS was found in LB and neither in any other loading direction. CL augmentation did not diminish differences in LB between CS and PS in the undecompressed state but led to an additional small AR reduction of 11% (0.15°) in CS and 7% (0.05°) in PS instrumentation.

CONCLUSION

Similar residual motion is found with CS and PS instrumentation, except of slightly, but significantly inferior reduction of ROM in LB with CS. Differences between CS and PS in diminish with TLIF but not with CL augmentation.

摘要

目的

比较皮质骨螺钉(CS)与椎弓根螺钉(PS)固定的腰椎节段的残余活动度(ROM),以及经椎间孔椎间融合术(TLIF)和横向连接(CL)增强的额外效果。

方法

记录35个新鲜人尸体腰椎节段在屈伸(FE)、侧方弯曲(LB)、侧方剪切(LS)、前方剪切(AS)、轴向旋转(AR)和轴向压缩(AC)时的ROM。在用PS(n = 17)和CS(n = 18)固定节段后,在减压和TLIF前后,分别评估有无CL增强时与未固定节段相比的ROM。

结果

CS和PS固定均显著降低了所有加载方向(AC除外)的ROM。在未减压节段,与PS的71%(4.0°)相比,CS在LB方向的相对(和绝对)活动度降低显著更低,为61%(绝对3.3°)(p = 0.048)。在没有椎间融合的情况下,CS和PS固定节段之间的FE、AR、AS、LS和AC值相似。减压和TLIF植入后,CS和PS在LB方向以及任何其他加载方向均无差异。CL增强在未减压状态下并未减少CS和PS在LB方向的差异,但导致CS固定节段的AR额外小幅降低11%(0.15°),PS固定节段降低7%(0.05°)。

结论

CS和PS固定的残余活动度相似,但CS在LB方向的ROM降低略小但显著更低。CS和PS之间的差异在TLIF后减小,但CL增强后未减小。